Soldier Study Guide · MOS study guides

25U Signal Support Systems Specialist study guide

257 flashcards in 12 modules. Search and study in the interactive app.

Study MOS 25U (Signal Support Systems Specialist) with plain-language flashcards for your Army job, board prep, and related tasks. Check current Army publications for the latest updates.

Looking for a different job? Browse all Army MOS flashcards.

Study modules

25U – Career Map Positions, Critical Development, Certifications and Training

Source: CMF 25 NCO Evaluation Board Supplement (board products, 25 Jun 2024; Army G-1 DA Pam 600-25 CMF 25 update of that date), MOS 25U pages. Public PDF at api.army.mil (cmf-25-board-products-25-jun-24.pdf). Complements mos-25u-signal-support.txt and mos-25u-2.txt through mos-25u-9.txt and does not repeat their 10C skill-level duties, 25U-to-25Z conversion, or TOC/CP/vehicle-platform workplace card. The Army G-1 Smartbook page also lists a 25 Aug 2026 CMF 25 board brief that was not retrieved. Public information only. Verify current editions.

25U: In the CMF 25 career progression supplement, what duty positions and months of time are listed as most qualified for a 25U staff sergeant and sergeant first class?
Most qualified looks like 24 or more months as a section chief or radio retransmission supervisor for a staff sergeant, and 24 or more months as a platoon or detachment sergeant for a sergeant first class. Highly qualified looks like 18 to 24 months in those same positions.
CMF 25 NCO Evaluation Board Supplement (board products, 25 Jun 2024), MOS 25U pages (Leadership Positions)
25U: Which career-development assignments does the CMF 25 MOS 25U page list as critical development for a staff sergeant?
Signal operations NCO, forward signal support NCO, signal tactical-network NCO, signal advisor, geographic combatant command or Army Service component command communications NCO, and senior signal maintenance NCO.
CMF 25 NCO Evaluation Board Supplement (board products, 25 Jun 2024), MOS 25U pages (Assignments)
25U: Which career-development assignments does the CMF 25 MOS 25U page list as critical development for a sergeant first class?
Senior signal operations NCO and senior geographic combatant command or Army Service component command communications NCO.
CMF 25 NCO Evaluation Board Supplement (board products, 25 Jun 2024), MOS 25U pages (Assignments)
25U: What civilian certifications and college levels does the CMF 25 board supplement list as most qualified for 25U staff sergeants and sergeants first class?
For a staff sergeant, Advanced Leaders Course distinguished honor graduate or honor graduate, 30 or more credit hours, and CompTIA A+ certification. For a sergeant first class, Senior Leaders Course distinguished honor graduate or honor graduate, an associate degree, and CompTIA Network+ certification.
CMF 25 NCO Evaluation Board Supplement (board products, 25 Jun 2024), MOS 25U pages (Military/Civilian Education/Certifications)
25U: What 25U-specific training courses does the CMF 25 career supplement list as most qualified for a staff sergeant and a sergeant first class?
For a staff sergeant, Ranger School, jumpmaster, Battle Staff NCO Course, Signal Digital Master Gunner, and Management Client Course. For a sergeant first class, Ranger School, jumpmaster, Battle Staff NCO Course, Signal Digital Master Gunner, SHARP, and the Joint C4 Planner Course.
CMF 25 NCO Evaluation Board Supplement (board products, 25 Jun 2024), MOS 25U pages (Training)

25U – Deep Dive 2: Qualifications, Radio Networks & Retransmission

Source: DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-25U); DA Pam 611-21 ch. 10 classification listing (chapter-10-base, Nov 2025); ATP 6-02.53 (Techniques for Tactical Radios and Retransmission, 31 Jul 2025). Verify current editions on armypubs.army.mil.

25U (10C): What ASVAB line scores qualify for 25U?
Both a minimum of 95 in EL (Electronics) and 95 in SC (Surveillance and Communications).
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U b(3)(a)
25U (10C): What physical demands rating and profile does 25U require?
Moderate (Gold) and a physical profile of 111221.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U b(1)-(2)
25U (10C): What are the minimum OPAT scores for 25U?
Long Jump 120 cm, Seated Power Throw 350 cm, Strength Deadlift 120 lbs, and Interval Aerobic Run 36 shuttles (Moderate/Gold).
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U b(3)(b)
25U (10C): What security clearance does 25U need?
SECRET eligibility, for initial award and to keep the MOS.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U b(5)
25U (10C): Besides ASVAB, clearance and OPAT, list the other initial-award requirements.
Normal color vision; U.S. citizen; and completion of the 25U course under the U.S. Army Signal School.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U b(4), b(6), b(7)
25U (10C): List all the ASIs 10C ties to 25U.
J7 WHCA Console Control Operations; Q6 Protection Cell Operations (SL 4-6, effective Oct 2024); W8 Special Forces Military Free Fall Operations; 5C Mission Command Digital Master Gunner (MCDMG).
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U c(1)-(4)
25U (10C): What maintenance level does a 25U perform on C&E systems and COMSEC devices?
Field level unit maintenance, plus preparing maintenance and supply requests for field level signal support.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U a
25U (10C): Besides radios, what vehicle and power equipment does a 25U perform PMCS on?
Assigned vehicles and power generators.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U a
25U (10C): What does "IOM" mean in the 25U duty description?
Install, operate, and maintain (for example, "IOMs RETRANS operations").
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U a and a(1) (IOM used with "installs, operates, and maintains" RETRANS)
25U (10C): A skill level 1 25U works with POR and COTS equipment in which three places?
The TOC, the CP, and vehicle platforms.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U a(1)
25U (10C): At which skill level does 10C first list recognizing ECM and implementing ECCM?
Skill level 2 (25U2O).
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U a(2)
25U (10C): Name three tasks 10C adds at skill level 4 (SFC).
Any three: plans and requests signal logistics support; develops and implements battalion and company signal training; helps develop signal policies, OPORD annexes and reports; coordinates external signal support; gives technical advice to commanders; plans and directs the RETRANS team.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U a(4); ch. 10 classification listing (chapter-10-base): 25U4 = E7
25U (10C): Since when has the current 10C 25U entry been effective?
The 10C heading shows 25U "effective 202510" (October 2025).
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-25U heading
25U (10C): In the classification listing, where did 25C Radio Operator-Maintainer skill levels 1-3 go?
Their rows, dated October 2021 (202110), carry the remark "MOS transfers to 25U."
DA Pam 611-21 ch. 10 classification listing (chapter-10-base, Nov 2025), 25C1-25C3 rows (202110, "MOS/TRANSFERS TO 25U")
25U radio: What are the most common RF ranges for tactical radios?
HF 3-30 MHz; VHF 30-300 MHz; UHF 300-3,000 MHz.
ATP 6-02.53 (31 Jul 2025), para 1-26
25U radio: List the tactical radio capabilities in ATP 6-02.53.
Automatic link establishment (ALE); anti-jamming; beyond line of sight; data rates; GPS; programmable (software defined); secure communications.
ATP 6-02.53 (31 Jul 2025), para 1-28
25U radio: What is the primary function of tactical radio networks?
Voice communication and situational awareness at all echelons and in all phases. Data is a secondary role where other data capabilities don't exist.
ATP 6-02.53 (31 Jul 2025), para 1-38
25U radio: Name the systems ATP 6-02.53 includes in the tactical radio network.
Combat net radios; vehicular and dismounted radios; Joint Battle Command Platform; Nett Warrior; Blue Force Tracker (I, II, III); MUOS; Integrated Tactical Network (ITN).
ATP 6-02.53 (31 Jul 2025), para 1-38
25U radio: Is the Integrated Tactical Network (ITN) a single program of record?
No. It combines developing tactical network capabilities with commercial and non-developmental items, fielded through network baselines for brigade and below.
ATP 6-02.53 (31 Jul 2025), para 1-39
25U radio: What does TSM stand for in the ITN?
Tactical scalable mobile ad hoc network: commercial waveforms enabling multipath network diversity.
ATP 6-02.53 (31 Jul 2025), para 1-39
25U radio: List the tactical radio networks commonly used by maneuver elements.
Command; sustainment; operations and intelligence; medical; fires; surveillance.
ATP 6-02.53 (31 Jul 2025), para 1-41
25U radio: Define a communications network (ATP 6-02.53).
An organization of stations capable of intercommunications, but not necessarily on the same channel.
ATP 6-02.53 (31 Jul 2025), para 1-42
25U radio: Besides SINCGARS, what means may support command networks?
HF; narrowband (single-channel) TACSAT; MUOS; and networking waveforms such as TSM and WREN (Warrior Robust Enhanced Network).
ATP 6-02.53 (31 Jul 2025), para 1-43
25U radio: Which network has the highest installation priority?
The command network.
ATP 6-02.53 (31 Jul 2025), para 1-46
25U radio: In which OPORD annex is the PACE plan published?
Annex H.
ATP 6-02.53 (31 Jul 2025), para 1-44
25U radio: What should PACE rehearsals include besides the order of means?
The commander's priorities for bandwidth allocation and order of restoration when links are denied or degraded.
ATP 6-02.53 (31 Jul 2025), para 1-45
25U radio: Who controls the operations and intelligence (O&I) network?
The G-2 or S-2.
ATP 6-02.53 (31 Jul 2025), para 1-48
25U radio: What is the highest priority network for fires units?
The fires network (exchange of technical and firing data; FISTs send calls for fire on it).
ATP 6-02.53 (31 Jul 2025), para 1-50
25U radio: Who establishes the surveillance network, and what does it control?
The battalion battlefield information control center; it controls ground surveillance radar and unattended ground sensor teams.
ATP 6-02.53 (31 Jul 2025), para 1-51
25U radio: What is the sustainment network used for?
Status reporting of sustainment, logistics, and administrative information.
ATP 6-02.53 (31 Jul 2025), para 1-47
25U radio: List the brigade S-6's tactical radio responsibilities in ATP 6-02.53.
Scheme of signal support (with PACE plans per phase); spectrum management coordination; deconflicting spectrum with the CEMA section; COMSEC account management; planning retrans operations; overseeing radio maintenance and logistics readiness.
ATP 6-02.53 (31 Jul 2025), para 2-13
25U retrans: Which unit provides voice and data retransmission for the brigade?
The brigade signal company.
ATP 6-02.53 (31 Jul 2025), para 2-14
25U retrans: Besides extending range, what can retransmission bridge?
Separate radio nets and modes (for example, frequency hopping to single-channel); it can also support mission partner networking or a counter-EW plan.
ATP 6-02.53 (31 Jul 2025), para 2-20
25U retrans: Who makes up a typical retrans team, and how many teams per echelon?
Two crew members and a team chief. Corps and brigade: two teams; division: up to three.
ATP 6-02.53 (31 Jul 2025), para 2-22
25U retrans: Does a retrans site extend range by increasing transmit power?
No. It increases effective range between stations without increasing transmit power.
ATP 6-02.53 (31 Jul 2025), para 2-23
25U retrans: Who recommends signal site locations for each COA?
The G-6 or S-6, based on signal site analysis during the MDMP.
ATP 6-02.53 (31 Jul 2025), para 2-24
25U retrans: What can poor retrans site placement cause?
Limited flexibility and mobility, threat detection, degraded survivability, and reduced effectiveness.
ATP 6-02.53 (31 Jul 2025), para 2-25
25U retrans: Name the three SINCGARS retransmission options.
Single-channel to single-channel; frequency hopping to single-channel (mixed mode); frequency hopping to frequency hopping.
ATP 6-02.53 (31 Jul 2025), para 2-32
25U retrans: What frequency separation does single-channel to single-channel retrans need?
At least 10 MHz, to avoid interference. Frequency hopping to single-channel is not limited by this separation.
ATP 6-02.53 (31 Jul 2025), para 2-33
25U retrans: F1:F1 vs F1:F2 frequency-hopping retrans?
F1:F1 uses the same network identifier on both radios (newer radios use a time delay). F1:F2 uses two radios with different network identifiers, suited to legacy SINCGARS.
ATP 6-02.53 (31 Jul 2025), paras 2-34, 2-35
25U retrans: During a retrans mission, what must one team member always do?
Continuously monitor radio traffic; that member also serves as shift relief for operations and site defense.
ATP 6-02.53 (31 Jul 2025), para 2-36
25U retrans: What should retrans team specified tasks include about loss of contact?
Criteria for ending or changing the mission if contact with higher is lost, including triggers to displace to an alternate site.
ATP 6-02.53 (31 Jul 2025), para 2-37

25U – Deep Dive 3: Retrans Missions, Radio Planning, PACE & Signature Control

Source: ATP 6-02.53 (Techniques for Tactical Radios and Retransmission, 31 Jul 2025), ch. 2-3. Verify current edition on armypubs.army.mil.

25U retrans: Who conducts pre-combat checks and inspections of retrans teams, and why are they so important?
The platoon leader or platoon sergeant. Remote teams are hard to reach and resupply, so detailed PCIs happen before they leave the staging area.
ATP 6-02.53 (31 Jul 2025), para 2-26
25U retrans: Which GTA covers retrans team pre-combat checks and inspections?
GTA 11-02-001 (with ATP 6-02.2).
ATP 6-02.53 (31 Jul 2025), para 2-26
25U retrans: How do leaders confirm team chiefs understood the pre-mission brief?
They have the team chief back brief portions of the plan.
ATP 6-02.53 (31 Jul 2025), para 2-27
25U retrans: Name six items in the retrans pre-mission briefing.
Any six: commander's intent; convoy plan; PACE plan; frequencies; COMSEC; jamming plan; supported unit's scheme of maneuver; supporting units; enemy situation; terrain masking; primary and alternate sites with movement triggers; antenna placement; site security and defense; compromise plan; resupply plan; reporting procedures.
ATP 6-02.53 (31 Jul 2025), para 2-27
25U retrans: What two parts make up the retrans compromise plan?
An emergency destruction plan (COMSEC, documents, maps, equipment) and an escape and evasion plan.
ATP 6-02.53 (31 Jul 2025), para 2-27
25U retrans: Name the two terrain masking techniques in the pre-mission brief.
Avoiding skylining, and using terrain to mask transmissions from enemy detection.
ATP 6-02.53 (31 Jul 2025), para 2-27
25U retrans: What do retrans teams use to give an overview of the proposed location and equipment?
Network diagrams; they also do risk assessments and terrain analysis of the site.
ATP 6-02.53 (31 Jul 2025), para 2-29
25U retrans: If terrain blocks line of sight for retrans, what may be needed?
SATCOM or HF radios for beyond line of sight communication.
ATP 6-02.53 (31 Jul 2025), para 2-29
25U retrans: Where are retrans team specified tasks given?
In the operation order.
ATP 6-02.53 (31 Jul 2025), para 2-30
25U retrans: What equipment does retransmission normally require?
Two tactical radios, one retrans cable, two power amplifiers, two antennas, and appropriate COMSEC.
ATP 6-02.53 (31 Jul 2025), para 2-31
25U retrans: Name three battle drills leaders should build into retrans training.
Gas attack, indirect fire, and emergency destruction drills.
ATP 6-02.53 (31 Jul 2025), para 2-39
25U retrans: Who conducts on-site post-mission checks if the PL or PSG isn't there?
The team chief.
ATP 6-02.53 (31 Jul 2025), para 2-40
25U retrans: Which two nets should be in the convoy frequency plan before leaving the site?
The sheriff net (quick-reaction force) and medical evacuation.
ATP 6-02.53 (31 Jul 2025), para 2-40
25U retrans: After returning, what is checked immediately?
Weapons, sensitive items, and ammunition.
ATP 6-02.53 (31 Jul 2025), para 2-41
25U retrans: Where do after-action review comments go after a retrans mission?
To higher headquarters, for lessons learned and SOP updates (after an internal AAR).
ATP 6-02.53 (31 Jul 2025), para 2-41
25U planning: What establishes the basis for tactical radio network planning?
Information from the higher headquarters operation order.
ATP 6-02.53 (31 Jul 2025), para 3-1
25U planning: On what mission variables do signal planners base support requirements?
METT-TC (I): mission, enemy, terrain and weather, troops and support available, time available, civil considerations, and informational considerations.
ATP 6-02.53 (31 Jul 2025), paras 1-44, 3-2
25U planning: What is a running estimate used for?
To continuously assess whether operations follow the commander's intent and are supportable and feasible; signal staffs use it to advise the commander.
ATP 6-02.53 (31 Jul 2025), para 3-3
25U planning: Besides communications suitability, what two things does radio site selection consider?
Defensibility and logistical supportability.
ATP 6-02.53 (31 Jul 2025), para 3-4
25U planning: What limits how much cover and concealment may impair communications?
The range required, transmitter power, receiver sensitivity, antenna efficiency, and the terrain.
ATP 6-02.53 (31 Jul 2025), para 3-5
25U site: For frequencies above 30 MHz, what kind of location is needed?
One that allows line of sight communications.
ATP 6-02.53 (31 Jul 2025), para 3-6
25U site: How does ground moisture affect radio range?
Dry ground has high resistance and limits range; moist ground is better, and water (especially fresh water) greatly increases range.
ATP 6-02.53 (31 Jul 2025), para 3-6
25U site: Why avoid tunnels, underpasses, and steel bridges for a radio site?
They absorb a lot of RF energy.
ATP 6-02.53 (31 Jul 2025), para 3-6
25U site: Why avoid heavily traveled roads for a radio site?
Noise and confusion from vehicles, and vehicle ignition systems can cause electrical interference.
ATP 6-02.53 (31 Jul 2025), para 3-6
25U site: Where should generators and battery chargers go relative to radio sets?
Away from the radio sets. Radio stations should also not be close to one another.
ATP 6-02.53 (31 Jul 2025), para 3-6
25U planning: With which staff does the G-6/S-6 coordinate, and why?
G-3/S-3 for intent and COA support; G-2/S-2 for threat and countermeasures; the CEWO to minimize signal site signatures; G-4/S-4 for sustainment and repair.
ATP 6-02.53 (31 Jul 2025), para 3-7
25U planning: List the radio network planning tools in ATP 6-02.53.
Joint Automated Communications-Electronics Operating Instructions System; Ruggedized Applications Platform-Tactical Radios; Automated Communications Engineering Software; Electromagnetic Warfare Planning and Management Tool; Systems Planning, Engineering, and Evaluation Device; Voice of America Coverage Analysis Program; Naval Research Laboratory Builder.
ATP 6-02.53 (31 Jul 2025), para 3-8
25U planning: What is Atom?
The primary Ruggedized Applications Platform-Tactical Radio software: a radio planning and loading tool for tactical radios and legacy and advanced waveforms.
ATP 6-02.53 (31 Jul 2025), para 3-10
25U planning: What does Automated Communications Engineering Software do?
Plans, creates, distributes, manages, and verifies cryptonets and key information; also SOI and electromagnetic protection planning.
ATP 6-02.53 (31 Jul 2025), para 3-11
25U planning: Which electronic fill device does Automated Communications Engineering Software provide fills for?
The AN/PYQ-10, by direct cable or over-the-air rekey.
ATP 6-02.53 (31 Jul 2025), para 3-12
25U planning: Which tool senses emitter activity and integrates electromagnetic order of battle data?
The Electromagnetic Warfare Planning and Management Tool.
ATP 6-02.53 (31 Jul 2025), para 3-15
25U planning: Which tools does ATP 6-02.53 name for HF planning?
The Systems Planning, Engineering, and Evaluation Device, and the Voice of America Coverage Analysis Program.
ATP 6-02.53 (31 Jul 2025), para 3-53
25U planning: Where can you get the public release of the Voice of America Coverage Analysis Program?
From the Department of Commerce National Telecommunications and Information Administration, Institute for Telecommunications Sciences (an HF prediction tool).
ATP 6-02.53 (31 Jul 2025), para 3-18
25U planning: What can the Interactive Scenario Builder (Builder) be used for, and on which networks?
Pre-mission planning, near real-time SA, and AARs; it is authorized on NIPRNet and SIPRNet.
ATP 6-02.53 (31 Jul 2025), para 3-19
25U COMSEC: Which three network plan categories does Automated Communications Engineering Software have planning modules for?
Combat net radios; general-purpose networks; adaptive networking wideband waveform.
ATP 6-02.53 (31 Jul 2025), para 3-22
25U COMSEC: For a cryptonet to talk securely, what must all members have?
Compatible equipment and keying material.
ATP 6-02.53 (31 Jul 2025), para 3-24
25U COMSEC: Who appoints the COMSEC account manager?
The commander, who carries responsibility for safeguarding COMSEC material in the unit.
ATP 6-02.53 (31 Jul 2025), para 3-25
25U COMSEC: At what echelon do users hold keying material and devices?
The lowest echelon that can maintain adequate physical security (accounting stays centralized).
ATP 6-02.53 (31 Jul 2025), para 3-26
25U COMSEC: What is the Army's primary means of transferring keying material?
Electronic key generation and distribution, using a fill device.
ATP 6-02.53 (31 Jul 2025), para 3-27
25U COMSEC: COMSEC "transfer" vs "issue"?
Transfer moves material and accountability from one account to another. Issue goes from an account to a local element, and the issuing account keeps accountability.
ATP 6-02.53 (31 Jul 2025), para 3-27
25U COMSEC: When may the NCS start over-the-air key distribution, and what must it do first?
Any time in the effective crypto period or just before it ends. It first notifies all recipients over a secure link.
ATP 6-02.53 (31 Jul 2025), para 3-29
25U COMSEC: If a keyed radio or loaded fill device is captured, what should the SOP assume?
That the enemy can operate it, listen to the secure hopping net, and transmit on it. Emergency key supersession follows.
ATP 6-02.53 (31 Jul 2025), para 3-30
25U EMCON: What three forms can radio discipline take?
Limiting transmissions, antenna masking, and using the minimum required power.
ATP 6-02.53 (31 Jul 2025), para 3-34
25U EMCON: Do brevity codes and prowords provide security?
No. They only shorten messages; they do not conceal content.
ATP 6-02.53 (31 Jul 2025), para 3-34
25U EMCON: What is a significant EMCON advantage of TACSAT systems?
Data burst transmission capability.
ATP 6-02.53 (31 Jul 2025), para 3-34
25U EMCON: Besides EMCON, what two protective measures does the CEWO help plan for critical nodes?
Electromagnetic masking and electromagnetic decoys.
ATP 6-02.53 (31 Jul 2025), para 3-33
25U spectrum: What is "frequency fratricide"?
Unintended electromagnetic interference by friendly spectrum-dependent devices with friendly communications, UAS, weapons, or GPS equipment.
ATP 6-02.53 (31 Jul 2025), para 3-35
25U spectrum: List the spectrum planning considerations in ATP 6-02.53.
Transmitter and receiver locations; antenna parameters; number of frequencies and separation; nature of operation (fixed, mobile land, airborne, maritime); physical effects of the environment; start and end dates; the joint restricted frequency list.
ATP 6-02.53 (31 Jul 2025), para 3-36
25U PACE: Does a PACE plan apply to a unit or a mission?
To a specific mission or task, not a unit.
ATP 6-02.53 (31 Jul 2025), para 3-39
25U PACE: Should non-mission-capable equipment be in the PACE plan?
No. The unit must be able to operate every means in its PACE plan.
ATP 6-02.53 (31 Jul 2025), para 3-42
25U PACE: What two essential elements does a unit check in a higher HQ's PACE plan?
Availability of assets to execute the plan to higher, and the ability to nest with higher's PACE plan.
ATP 6-02.53 (31 Jul 2025), para 3-42
25U PACE: What must a unit do if it can't execute the full PACE plan to higher?
Tell the issuing headquarters, with shortfalls, gaps, and mitigation, during mission analysis.
ATP 6-02.53 (31 Jul 2025), para 3-43
25U PACE: In the ATP 6-02.53 example (table 3-1), what is the primary means for command and control?
VHF (command net). Alternate: SC TACSAT; contingency: JBCP; emergency: HF (chat).
ATP 6-02.53 (31 Jul 2025), table 3-1
25U PACE: In the table 3-1 example, what are the primary means for intelligence and for fires?
Intelligence: DCGS-A. Fires: AFATDS.
ATP 6-02.53 (31 Jul 2025), table 3-1
25U signature: What does proper link geometry do?
Masks signals from threat direction-finding and jamming.
ATP 6-02.53 (31 Jul 2025), para 3-45
25U signature: List the three measures leaders combine to mask site signatures.
Camouflage and concealment; noise and light discipline; electromagnetic signature reduction.
ATP 6-02.53 (31 Jul 2025), para 3-46
25U signature: How should antennas be placed for concealment?
As low as possible, on the backside of terrain features and behind man-made obstacles.
ATP 6-02.53 (31 Jul 2025), para 3-47
25U signature: How do antenna multiplexers help?
They reduce the number of antennas needed, shrinking the electromagnetic footprint.
ATP 6-02.53 (31 Jul 2025), para 3-48
25U signature: Give three noise discipline practices at a signal site.
Any three: turn off equipment not in use; mask noise with cover or walls; limit radio use; restrict vehicle and foot movement; secure loose metal parts; turn speaker volume to the lowest setting.
ATP 6-02.53 (31 Jul 2025), para 3-49
25U signature: Name two light discipline practices during site setup.
Minimize flashlight use, and cover or blacken reflective surfaces such as bare metal or windshields (and consider threat night vision when using IR).
ATP 6-02.53 (31 Jul 2025), para 3-50
25U signature: How do leaders minimize the unit's electromagnetic signature?
Use digital rather than analog C2, apply electromagnetic protection techniques, and set EMCON procedures.
ATP 6-02.53 (31 Jul 2025), para 3-51
25U SOI: What do signal operating instructions contain?
Unit radio nets, assigned net control stations, primary and alternate frequencies per net, communications priorities and protocol, and authentication and COMSEC guidance.
ATP 6-02.53 (31 Jul 2025), para 3-52
25U HF: What must HF planners determine to find the most favorable conditions?
The optimal frequency, time of day, power, and antenna configuration.
ATP 6-02.53 (31 Jul 2025), para 3-53
25U HF: What four concepts must planners understand to select an HF antenna?
Wavelength, frequency, resonance, and polarization.
ATP 6-02.53 (31 Jul 2025), para 3-54
25U TACSAT: Which tool is used to prepare and submit narrowband satellite access requests, and on which network?
The Joint Integrated Satellite Communications Tool, on SIPRNet.
ATP 6-02.53 (31 Jul 2025), paras 3-55, 3-58
25U TACSAT: Why locate TACSAT antennas away from command posts?
To limit collateral damage if the communications systems are destroyed.
ATP 6-02.53 (31 Jul 2025), para 3-56
25U TACSAT: How far ahead must a satellite access request reach the regional SATCOM support center?
30 days before the requested access date (shorter for exception, crisis, or contingency requests).
ATP 6-02.53 (31 Jul 2025), para 3-58
25U TACSAT: Where do CONUS units send satellite access requests for validation?
To FORSCOM. Units overseas send them to the theater army SATCOM manager.
ATP 6-02.53 (31 Jul 2025), para 3-58

25U – Deep Dive 4: SATCOM, Data Networks, Retrans Site Planning & COMSEC Incidents

Source: ATP 6-02.53 (Techniques for Tactical Radios and Retransmission, 31 Jul 2025), ch. 3 paras 3-59 to 3-95. Verify current edition on armypubs.army.mil.

25U SATCOM: What is DAMA?
Demand-assigned multiple access: a technique that matches user demands to available satellite bandwidth by assigning variable time slots, so users share channels.
ATP 6-02.53 (31 Jul 2025), para 3-59
25U SATCOM: By how much does DAMA generally increase satellite capability?
About 5 to 14 times over dedicated channel operation.
ATP 6-02.53 (31 Jul 2025), para 3-59
25U SATCOM: What is the integrated waveform, and what does it replace?
An enhanced method of multiplexing radio networks on the same channel using carrier phase modulation. It replaces DAMA.
ATP 6-02.53 (31 Jul 2025), para 3-61
25U SATCOM: Name four SATCOM topics planners should be familiar with.
Any four: SATCOM database; requirements submission; degraded and denied operations; satellite access requests; access priorities; apportionment; access planning; redundant communications procedures; allocation process; after action reporting; planning checklist.
ATP 6-02.53 (31 Jul 2025), para 3-60
25U MUOS: What is MUOS "provisioning"?
Registering a terminal with the MUOS network management system and giving it access to operate in an approved configuration.
ATP 6-02.53 (31 Jul 2025), para 3-62
25U MUOS: What is a MUOS terminal made up of?
A combination radio and modem configuration.
ATP 6-02.53 (31 Jul 2025), para 3-62
25U MUOS: How early should terminal provisioning requests and satellite access requests be submitted?
No later than 90 days before the mission start date.
ATP 6-02.53 (31 Jul 2025), para 3-63
25U MUOS: To whom must a compromise or loss of a MUOS terminal profile be reported?
The Global Narrowband Watch Office or a regional satellite communications support center.
ATP 6-02.53 (31 Jul 2025), para 3-63
25U MUOS: How are legacy TACSAT users bridged to MUOS users?
Through a MUOS legacy gateway component, which needs significant coordination with MUOS network control centers and end users.
ATP 6-02.53 (31 Jul 2025), para 3-64
25U data networks: Define electromagnetic order of battle (JP 3-85).
A subset of the order of battle: the identification, strength, command structure, disposition, and operating parameters of the threat's spectrum-dependent systems.
ATP 6-02.53 (31 Jul 2025), para 3-66
25U data networks: Who collaborates on the electromagnetic protection plan?
G-6/S-6 planners, the G-2/S-2, the space operations officer, and the CEWO.
ATP 6-02.53 (31 Jul 2025), para 3-67
25U data networks: List the additional network planning considerations in para 3-67.
System and network availability; frequency allocation; IP planning; mission partner interoperability; frequency planning.
ATP 6-02.53 (31 Jul 2025), para 3-67
25U ITN: Which military standard is cited for safeguarding ITN systems?
MIL-STD-461G.
ATP 6-02.53 (31 Jul 2025), para 3-69
25U ITN: Where are spectrum supportability risk assessments submitted, and under which rules?
To the Army Spectrum Management Office, per DODI 4650.01 and AR 5-12, to get a spectrum supportability decision.
ATP 6-02.53 (31 Jul 2025), paras 3-70, 3-71
25U ITN: Which ATP covers frequency request procedures?
ATP 6-02.70.
ATP 6-02.53 (31 Jul 2025), para 3-71
25U ITN: Name three key requirements for ITN planning.
Any three: multi-mode equipment; customizable visual tools; real-time system health monitoring; multipath voice and data transport; multi-level security; data mediation; multi-source data access; system of systems architecture; transport compatibility and bandwidth aggregation; on-the-move comms; spectrum supportability risk assessment; automated PACE failover; radio network extension to augment retrans.
ATP 6-02.53 (31 Jul 2025), para 3-70
25U joint: Which theater army G-6 section maintains Global Command and Control System servers for the theater COP?
The joint and coalition network section.
ATP 6-02.53 (31 Jul 2025), para 3-73
25U retrans planning: Who can provide extra security or a response force for retrans sites in the support area?
Military police (see ATP 3-39.30).
ATP 6-02.53 (31 Jul 2025), para 3-74
25U retrans planning: Name the support tasks done by non-signal personnel that retrans relies on.
Quick reaction force, physical security, site defense, and casualty evacuation.
ATP 6-02.53 (31 Jul 2025), para 3-75
25U retrans planning: Which emergency contact frequencies should a retrans plan include?
Medical evacuation, command, and nearest units.
ATP 6-02.53 (31 Jul 2025), para 3-75
25U retrans planning: What example status-report interval does ATP 6-02.53 give for contacting the parent unit?
Contact the G-6 or S-6 every two hours with status reports (example; set by the plan).
ATP 6-02.53 (31 Jul 2025), para 3-75
25U retrans planning: What does a reseed plan cover?
Vehicles, radios, and personnel.
ATP 6-02.53 (31 Jul 2025), para 3-75
25U retrans planning: List the five retrans planning considerations in para 3-77.
Site analysis; site selection; site reconnaissance; site security and defense; sustainment and resupply.
ATP 6-02.53 (31 Jul 2025), para 3-77
25U retrans planning: In signal site analysis, what does the G-6/S-6 focus on vs the G-3/S-3?
G-6/S-6: the systems' ability to provide coverage from the site. G-3/S-3: mobility, survivability, and sustainability.
ATP 6-02.53 (31 Jul 2025), para 3-79
25U retrans planning: What does the G-6/S-6 get from the G-2/S-2 for site analysis?
Terrain analysis and the current threat estimate, so sites aren't near known or expected enemy positions.
ATP 6-02.53 (31 Jul 2025), para 3-81
25U retrans planning: Name the technical limitations of equipment the G-6/S-6 considers.
Range, weather, bandwidth, and frequencies.
ATP 6-02.53 (31 Jul 2025), para 3-82
25U retrans planning: If a site reconnaissance isn't possible, what can leaders use?
Line of sight analysis tools and satellite imagery.
ATP 6-02.53 (31 Jul 2025), para 3-83
25U retrans planning: Which enemy COAs should planners consider when evaluating retrans sites?
The enemy's most likely and most dangerous COAs.
ATP 6-02.53 (31 Jul 2025), para 3-83
25U retrans planning: The final retrans site must meet which four criteria?
Able to provide range extension; accessible; defensible (defensive plan, escape routes, cover, concealment); logistically supportable.
ATP 6-02.53 (31 Jul 2025), para 3-84
25U retrans planning: What are favorable retrans site locations?
Ridgelines and hilltops away from roads, trails, and natural lines of drift, with multiple escape routes; terrain flat enough for antennas.
ATP 6-02.53 (31 Jul 2025), para 3-86
25U retrans planning: If a retrans site operates remotely, what threat levels must its augmented security survive?
Ground attack or level II and III threats (see ATP 3-39.30).
ATP 6-02.53 (31 Jul 2025), para 3-88
25U retrans planning: Where should retrans sites supporting a mobile defense be located if possible?
Co-located with other Army elements.
ATP 6-02.53 (31 Jul 2025), para 3-88
25U retrans planning: For site defense, what does the planner coordinate with the G-2/S-2 and G-3/S-3?
G-2/S-2: the current threat estimate. G-3/S-3: security force arrangements.
ATP 6-02.53 (31 Jul 2025), para 3-89
25U retrans planning: Which classes of supply take priority for signal platoons?
Class I, III, and IX.
ATP 6-02.53 (31 Jul 2025), para 3-91
25U retrans planning: What are the two types of resupply operations?
Planned or emergency.
ATP 6-02.53 (31 Jul 2025), para 3-91
25U retrans planning: What crew drills should contingency rehearsals include?
Requests for indirect fire support, contingency actions, actions on contact, and emergency destruction.
ATP 6-02.53 (31 Jul 2025), para 3-92
25U retrans planning: List the example triggers for displacing to an alternate site.
Approaching enemy forces; receiving indirect fires; impending inclement weather; imminent wildfires.
ATP 6-02.53 (31 Jul 2025), para 3-93
25U COMSEC: When does a COMSEC compromise occur (ATP 6-02.53)?
When COMSEC material is irretrievable or lost, information is disclosed to unauthorized people, or a security policy violation may have caused unauthorized disclosure, modification, or destruction.
ATP 6-02.53 (31 Jul 2025), para 3-94
25U COMSEC: What minimum information do operators give the G-6/S-6 on a COMSEC compromise?
Unit; equipment type and nomenclature; crypto segment or period; time and location of the compromise. (First stop transmitting on the compromised system.)
ATP 6-02.53 (31 Jul 2025), para 3-94
25U COMSEC: List the reportable COMSEC incidents in ATP 6-02.53.
Loss of accountability; improper destruction; possible tampering; found on installation; unsecured or unauthorized access; improper storage; unauthorized use of keying material; loss of COMSEC material; loss of TPI for top secret key.
ATP 6-02.53 (31 Jul 2025), para 3-95

25U – Deep Dive 5: Electromagnetic Attack, Interference, JSIR & EMCON

Source: ATP 6-02.53 (Techniques for Tactical Radios and Retransmission, 31 Jul 2025), app. A (Recognizing and Responding to Electromagnetic Attack). Verify current edition on armypubs.army.mil.

25U EA: When threat forces locate friendly units, what three priorities do their information warfare elements set?
Jam communications assets; deceptively enter radio networks; interfere with the normal flow of U.S. and allied communications.
ATP 6-02.53 (31 Jul 2025), para A-3
25U EA: Why does preventing detection also prevent jamming and geolocation?
If a threat cannot detect friendly signals, it cannot geolocate or jam them.
ATP 6-02.53 (31 Jul 2025), para A-5
25U EA: List the measures to reduce the electromagnetic signature of CPs and comms sites.
Careful site selection; directional antennas; lowest power required; limiting transmissions; burst transmission; a random battle rhythm schedule.
ATP 6-02.53 (31 Jul 2025), para A-6
25U EA: How does terrain masking block threat direction finding?
By putting large terrain features or man-made structures between the comms system and the forward line of own troops.
ATP 6-02.53 (31 Jul 2025), para A-8
25U EA: How does radar reflective camouflage netting help a directional antenna?
Placed to the sides and back, it blocks unintended radiation so only the highly directional main beam radiates.
ATP 6-02.53 (31 Jul 2025), para A-9
25U EA: How far can high-throughput line of sight radios carry data, and how should the path be oriented?
Up to 25 miles. A path parallel to the forward line of troops is harder to detect and jam.
ATP 6-02.53 (31 Jul 2025), para A-10
25U EA: Why place major comms assemblages far from the supported CP?
Peer threats target C2 emitters with lethal fires; distance or terrain protects the CP (but adds site security needs).
ATP 6-02.53 (31 Jul 2025), paras A-11, A-12
25U EA: Why move command posts frequently?
A peer threat will likely locate the CP eventually; frequent moves reduce the chance of destruction, especially within enemy artillery range.
ATP 6-02.53 (31 Jul 2025), para A-13
25U EA: Who is in the CEMA section?
The CEWO, the spectrum manager, the electromagnetic warfare technician, and EW NCOs (brigade to corps).
ATP 6-02.53 (31 Jul 2025), para A-17
25U EA: Which annex does the G-6/S-6 prepare, and what does it cross-reference?
Annex H (Signal), cross-referenced to the EW parts of annex C, the OPSEC part of annex E, the MILDEC plan, and the SOI.
ATP 6-02.53 (31 Jul 2025), para A-19
25U EA: What three frequency types are on the joint restricted frequency list?
Taboo, protected, and guarded frequencies (disseminated by the G-6/S-6).
ATP 6-02.53 (31 Jul 2025), para A-19
25U EA: Which staff section has staff responsibility for electromagnetic protection?
The G-3 or S-3.
ATP 6-02.53 (31 Jul 2025), para A-20
25U EA: Who leads the CEMA working group?
The CEWO.
ATP 6-02.53 (31 Jul 2025), paras A-18, A-21
25U EA: What does the G-2/S-2 intelligence estimate give signal planners?
Current enemy TTPs; enemy locations relative to friendly forces; the enemy's electromagnetic order of battle; known cyberspace threats.
ATP 6-02.53 (31 Jul 2025), para A-24
25U jamming: Do jammers operate against transmitters or receivers?
Receivers.
ATP 6-02.53 (31 Jul 2025), para A-27
25U jamming: Spot vs barrage jamming?
Spot concentrates power on one channel or frequency. Barrage spreads power over several frequencies at once.
ATP 6-02.53 (31 Jul 2025), para A-27
25U jamming: Name the causes of unintentional electromagnetic interference.
Other radios (friendly and enemy); other electronic, electrical or electromechanical equipment; atmospheric conditions; equipment malfunction.
ATP 6-02.53 (31 Jul 2025), para A-28
25U jamming: Which radios does jamming most commonly affect?
Single-channel radio systems (HF, VHF, and UHF).
ATP 6-02.53 (31 Jul 2025), para A-29
25U jamming: What is subtle jamming?
Jamming that produces no sound; the radio seems normal but can't receive friendly signals, so users often think it is broken.
ATP 6-02.53 (31 Jul 2025), para A-30
25U jamming: Which GTA covers electromagnetic attack TTPs?
GTA 13-01-001.
ATP 6-02.53 (31 Jul 2025), para A-30
25U jamming: Name the eight common jamming signals in table A-1.
Random noise; stepped tones; spark; gulls; random pulse; recorded sounds; wobbler; preamble jamming.
ATP 6-02.53 (31 Jul 2025), table A-1
25U jamming: Which jamming signal sounds like bagpipes?
Stepped tones (rising and falling pitch), effective against single-channel AM or FM voice.
ATP 6-02.53 (31 Jul 2025), table A-1
25U jamming: Which jamming signal sounds like a seagull?
Gulls (quickly rising, slowly falling RF).
ATP 6-02.53 (31 Jul 2025), table A-1
25U jamming: Which jamming is easy to produce and disrupts all types of radio communications?
Spark: short, high-intensity bursts repeated rapidly.
ATP 6-02.53 (31 Jul 2025), table A-1
25U jamming: What does preamble jamming do?
It sends a tone like the speech security sync preamble, locking all radios in receive mode.
ATP 6-02.53 (31 Jul 2025), table A-1
25U jamming: Why is random noise jamming dangerous?
It looks like normal receiver or atmospheric noise, so operators fail to take protective action.
ATP 6-02.53 (31 Jul 2025), table A-1
25U jamming: What is the optimal maximum length of a radio transmission to reduce jamming risk?
Six seconds or less.
ATP 6-02.53 (31 Jul 2025), paras A-31, A-41
25U jamming: List the preventive measures against communications jamming.
Minimize transmissions; use ECCM such as frequency hopping; train with radio silence; use low power normally; use terrain masking.
ATP 6-02.53 (31 Jul 2025), para A-31
25U jamming: Why should operators keep operating normally while jammed?
The enemy jams, then listens briefly. Discussion on the air or shutting down tells them it worked. Never end a net unless ordered.
ATP 6-02.53 (31 Jul 2025), para A-33
25U jamming: What is the signal-to-jamming ratio?
The relative strength of the desired signal to the jamming signal at the receiver.
ATP 6-02.53 (31 Jul 2025), para A-33
25U jamming: Name three ways to improve the signal-to-jamming ratio.
Adjust or change the antenna; establish a retrans site; relocate the antenna (possibly several hundred meters) to use terrain masking.
ATP 6-02.53 (31 Jul 2025), para A-33
25U jamming: When changing to an alternate frequency, how can the change be masked?
Preplanned dummy stations keep operating on the jammed frequency.
ATP 6-02.53 (31 Jul 2025), para A-33
25U jamming: If corrective actions work, what report is still submitted?
A joint spectrum interference resolution (JSIR) report to higher headquarters.
ATP 6-02.53 (31 Jul 2025), para A-34
25U PNT: About how many PNT-enabled and SATCOM-enabled devices does a typical BCT have?
Over 2,500 PNT-enabled and over 250 SATCOM-enabled devices.
ATP 6-02.53 (31 Jul 2025), para A-35
25U PNT: Name the systems affected by PNT jamming.
Communications; friendly force tracking; navigation; reconnaissance; radar; precision guided munitions.
ATP 6-02.53 (31 Jul 2025), para A-36
25U PNT: List the preventive measures for PNT jamming.
Use only encrypted PNT systems; antenna masking; terrain masking; train to navigate by map and compass.
ATP 6-02.53 (31 Jul 2025), para A-37
25U PNT: Name four indicators of GPS/PNT jamming.
Any four: loss of satellite signal; red GPS icon on the network management system; lost or wrong time; inaccurate map or position data; jamming environment warning message.
ATP 6-02.53 (31 Jul 2025), para A-38
25U PNT: What is the first listed reaction to GPS jamming, and why?
Navigate using map and compass, which cannot be jammed.
ATP 6-02.53 (31 Jul 2025), para A-39
25U SATCOM: When may a wideband SATCOM terminal operator increase power against jamming?
Only if directed by the satellite controller.
ATP 6-02.53 (31 Jul 2025), para A-43
25U SATCOM: Name three indicators of satellite jamming.
Any three: random noise on TACSAT; recorded sounds on TACSAT; no answer; red satellite icon on the network management display; loss of satellite data; low signal-to-noise on a wideband terminal.
ATP 6-02.53 (31 Jul 2025), para A-42
25U SATCOM: Why report jamming to higher headquarters?
Its frequency manager and CEWO correlate reports to isolate enemy jammers and plan countermeasures, including nominating targets for lethal fires.
ATP 6-02.53 (31 Jul 2025), para A-43
25U EMI: Define electromagnetic interference (JP 3-85).
Any electromagnetic disturbance, intentional or not, that interrupts, obstructs, degrades, or limits the performance of spectrum-dependent systems and electrical equipment.
ATP 6-02.53 (31 Jul 2025), para A-44
25U EMI: Give examples of natural and man-made EMI sources.
Natural: atmospheric noise (thunderstorms), galactic noise (stars), geographic phenomena. Man-made: power lines, generators, alarm systems, electrified railroads, fluorescent lights.
ATP 6-02.53 (31 Jul 2025), para A-45
25U EMI: Name the space weather factors that can affect signal transmission.
Solar radio bursts; noise storms; ionospheric scintillation; aurora activity; solar flares.
ATP 6-02.53 (31 Jul 2025), para A-47
25U EMI: Who issues real-time and forecast space weather data?
The Air Force Space Weather Operations Center.
ATP 6-02.53 (31 Jul 2025), para A-48
25U EMI: Name three ways to reduce cosite interference.
Transmit at the lowest power possible; remote the antennas and send low power to a full-power retrans system; separate antennas as much as possible (tilting tops apart 15-30 degrees helps).
ATP 6-02.53 (31 Jul 2025), para A-51
25U EMI: During interference events, what may the G-6/S-6 do with less critical systems?
Shut them down to preserve mission-critical systems, per a system priority list.
ATP 6-02.53 (31 Jul 2025), para A-51
25U JSIR: Which EMI disturbances must units report?
All of them, regardless of severity, intensity, or duration.
ATP 6-02.53 (31 Jul 2025), para A-52
25U JSIR: How are suspected hostile EMI reports submitted?
Through the secure JSIR-Online Portal. Don't wait for missing details; send follow-up reports.
ATP 6-02.53 (31 Jul 2025), para A-52
25U JSIR: Name five items in a JSIR report (table A-2).
Any five of 14: frequencies affected; locations of affected systems; system name and nomenclature; operating mode; interference characteristics; effects on performance; dates and times; possible source location; other units affected; narrative summary; related messages; whether resolved; whether technical help is wanted; POC info.
ATP 6-02.53 (31 Jul 2025), table A-2
25U JSIR: At what level should EMI problems be resolved first?
The lowest possible level, before submitting JSIR reports to higher.
ATP 6-02.53 (31 Jul 2025), para A-54
25U JSIR: What precedence is normally used for JSIR reports?
Routine or priority, unless the incident is hazardous to military operations.
ATP 6-02.53 (31 Jul 2025), para A-56
25U JSIR: Which CJCS manual covers JSIR procedures?
CJCSM 3320.02E.
ATP 6-02.53 (31 Jul 2025), paras A-57, A-58
25U JSIR: In the JSIR classification guide, how is suspected interference from friendly sources classified?
Unclassified, or Secret if it reveals a specific equipment vulnerability.
ATP 6-02.53 (31 Jul 2025), table A-3
25U EMI: List the six steps of the EMI battle drill (table A-4).
1 Troubleshoot equipment (frequency, cables, antenna, COMSEC). 2 Find start/stop times or duration. 3 Identify the effect (voice, noise, static). 4 Identify other emitters. 5 Check adjacent units. 6 Submit a JSIR report through the G-6/S-6 spectrum manager.
ATP 6-02.53 (31 Jul 2025), table A-4
25U EMCON: Define emission control (JP 3-85).
Selective, controlled use of emitters to optimize C2 while minimizing, for OPSEC, enemy detection, mutual friendly interference, and enemy interference with a MILDEC plan.
ATP 6-02.53 (31 Jul 2025), para A-60
25U EMCON: Name the five EMCON conditions and colors.
EMCON 1 Green; 2 Yellow; 3 Amber; 4 Red; 5 Black.
ATP 6-02.53 (31 Jul 2025), table A-5
25U EMCON: Which EMCON condition is the baseline during operations?
EMCON 3 (Amber). Units should routinely practice moving to EMCON 4 (Red) and 5 (Black) in conflict.
ATP 6-02.53 (31 Jul 2025), para A-61
25U EMCON: What happens to unencrypted systems at EMCON 3 (Amber)?
All unencrypted systems are disconnected; ECCM on important systems is a priority.
ATP 6-02.53 (31 Jul 2025), table A-5
25U EMCON: Describe EMCON 4 (Red) vs EMCON 5 (Black).
Red: an attack has taken place; non-essential emitters may go offline and alternate means may be used. Black: attacks are ongoing; the most restrictive protection is enforced and compromised systems are isolated.
ATP 6-02.53 (31 Jul 2025), table A-5
25U EMCON: In the table A-6 example, what are SINCGARS ASIP rules at EMCON 4 (Red) and 5 (Black)?
Red: encrypt, frequency hop, no more than 10 watts, directional antennas if available. Black: do not use.
ATP 6-02.53 (31 Jul 2025), table A-6
25U EMCON: Who helps determine emitter criteria for each EMCON condition?
The CEWO, assisting the G-3/S-3 and G-6/S-6. Every emitter should be in the matrix, which works with the PACE plan.
ATP 6-02.53 (31 Jul 2025), para A-62

25U – Corps and Division Signal Companies

Source: ATP 6-02.53, Techniques for Tactical Radio Operations (31 July 2025) para 2-6. Complements mos-25u-signal-support.txt and mos-25u-2.txt through mos-25u-5.txt and does not repeat their brigade-signal-company retransmission, retrans-team, or staff-coordination cards. Public information only. Verify current editions.

25U: Which companies at corps and division provide organic signal capabilities under the technical control of the G-6?
The signal portion of the corps and division signal, intelligence, and sustainment companies. Those companies provide organic signal capabilities, including tactical radio retransmission, for communication between higher, adjacent, and subordinate elements.
ATP 6-02.53 (31 Jul 2025) para 2-6

25U – Organic Signal Support at Brigade and Below

Source: ATP 6-02.53, Techniques for Tactical Radio Operations (31 July 2025) para 2-3. Complements mos-25u-signal-support.txt and mos-25u-2.txt through mos-25u-6.txt and does not repeat the para 2-6 expeditionary signal battalion card. Public information only. Verify current editions.

25U: At brigade, battalion, company, and platoon echelons, how do units employ tactical radios, and how far down do maneuver elements have organic single-channel secure radios?
Those echelons employ tactical radios to collaborate with adjacent units and higher reporting elements. Maneuver elements have limited organic signal capabilities consisting primarily of single-channel secure radios down to squad level. Their communications systems are mostly general-purpose, user-operated equipment. Brigade units rely on tactical radio retransmission networks to extend line-of-sight range.
ATP 6-02.53 (31 Jul 2025) para 2-3

25U – COMSEC Measures, Key Distribution, Emergency Destruction, and Joint Standards

Source: ATP 6-02.53, Techniques for Tactical Radio Operations (31 July 2025) paras 3-20, 3-21, 3-23, 3-31, 3-68, and 3-72. Complements mos-25u-signal-support.txt and mos-25u-2.txt through mos-25u-7.txt and does not repeat their 3-22, 3-24–3-27, 3-29–3-30, or 3-94–3-95 COMSEC cards. Public information only. Verify current editions.

25U: What protective measures does ATP 6-02.53 include in communications security (COMSEC)?
Protective measures to deny unauthorized access to information of value derived from use of communications systems (JP 6-0). Cryptographic systems and devices protect networks and the information being transmitted and give the command confidence in the security of transmissions. Leaders, network planners, and end users must guard against threat attempts to intercept and exploit U.S. operation plans through its networks and information services.
ATP 6-02.53 (31 Jul 2025) para 3-20
25U: What COMSEC overlay do operators develop from a PACE plan?
The COMSEC network overlay. The network planner tailors the software and workstations as needed using the general-purpose planning module. Once that work is complete, COMSEC account managers who keep centralized accountability of cryptographic material and equipment process the cryptonet plan for delivery and later distribution to the end user.
ATP 6-02.53 (31 Jul 2025) para 3-21
25U: How do the COMSEC account manager and users move keys onto end cryptographic units?
After the network planner finishes the cryptonet and provides the cryptonet plan, signal operating instructions, and loadset data to local end users, the COMSEC account manager generates or provisions and distributes the key by loading keys into the users’ fill devices. Users then load the end cryptographic units using a fill device.
ATP 6-02.53 (31 Jul 2025) para 3-23
25U: What COMSEC evacuation or destruction procedures must the unit SOP include?
Procedures to evacuate COMSEC material and encryption devices or destroy them in place. Including emergency destruction battle drills in mission rehearsals reduces the risk of system compromise and prepares the force to respond in real-world operations.
ATP 6-02.53 (31 Jul 2025) para 3-31
25U: Under ATP 6-02.53, what common application standards help extend data and voice support?
Common application standards, services infrastructure, and network transport. They give the integrated tactical network a broader range of capabilities to extend data and voice communication, when required, to Army and allied forces and mission partners.
ATP 6-02.53 (31 Jul 2025) para 3-68
25U: Under ATP 6-02.53, why are agreed-upon standards needed when building joint communications?
Agreed-upon standards for information and data exchange ensure cohesive integration of the network architecture, whether systems and capabilities are commercial off-the-shelf or are transport network capabilities or systems belonging to mission partners.
ATP 6-02.53 (31 Jul 2025) para 3-72

25U – Corps, Division and Brigade Signal Organization and Staff Responsibilities

Source: ATP 6-02.53, Techniques for Tactical Radio Operations (31 July 2025) paras 2-5, 2-7, 2-11, 2-12, 2-16 and 2-17–2-19. Complements mos-25u-signal-support.txt and mos-25u-2.txt through mos-25u-8.txt and does not repeat their para 2-3, 2-6, PACE, or retransmission-team cards. Public information only. Verify current editions.

25U: How do organic capabilities of the corps and division signal, intelligence, and sustainment companies differ by echelon?
They are employed in a similar way at each echelon to support intra-network communication between upper and lower echelons and to fuse data into a shareable common operational picture. The corps company employs HF radios, VHF radios, and narrowband (single-channel) TACSAT. The division company employs HF radios, SINCGARS, VHF radios, narrowband (single-channel) TACSAT, and MUOS.
ATP 6-02.53 (31 Jul 2025) para 2-7
25U: If a brigade combat team’s organic elements cannot provide a needed capability, from which higher echelon is it requested?
From division. The brigade’s organic assets support continuous operations to sustain the brigade’s communications networks. Brigade combat teams employ VHF; narrowband (single-channel) TACSAT and MUOS; HF; SINCGARS; Blue Force Tracker (Joint Battle Command Platform); and tactical networking waveforms such as TSM and WREN.
ATP 6-02.53 (31 Jul 2025) para 2-12
25U: Under whose technical control does the brigade’s signal company provide communications and information support at brigade level, and what two tasks does that company establish?
The brigade S-6. The company establishes tactical radio retransmission sites and establishes narrowband (single-channel) TACSAT at the brigade.
ATP 6-02.53 (31 Jul 2025) para 2-16
25U: What staff coordination is the G-6 responsible for so subordinate elements support operations, and which staff officer shares that task?
The G-6 is responsible for coordinating with the G-3 to direct the action of those elements through the orders process.
ATP 6-02.53 (31 Jul 2025) para 2-5
25U: What is the brigade S-6 responsible for when working closely with the deputy commander and the S-3?
The S-6 works closely with the deputy commander, the S-3, and other staff sections to define communications requirements and command post locations through the military decision-making process. The S-6 directs planning and coordination for tactical radio networks, spectrum management operations, retransmission, and COMSEC. The brigade S-6 also coordinates with the S-3 to direct the actions and movements of signal company elements through the orders process.
ATP 6-02.53 (31 Jul 2025) para 2-11
25U: Whom should the battalion S-6 keep a close working relationship with, and what is that officer responsible for in the assigned area?
The commander and the battalion S-3, so the communication plan supports the commander’s intent. The S-6 is responsible for supporting the commander’s communication requirements by providing advice to ensure effective communications connectivity within the assigned area.
ATP 6-02.53 (31 Jul 2025) paras 2-17 and 2-19

25U Final exam study guide

Source: DA Pam 611-21, Chapter 10C (October 2026 enlisted MOS specifications copy), paragraph 10-25U a(1)–(3). Public information only. Verify current editions. Complements mos-25u-signal-support.txt and mos-25u-2.txt and does not repeat those duty cards word for word. No public STP or critical-task list for 25U was on disk for this pass, and no exam questions or passing scores are invented here.

25U (review): Besides working in the TOC, CP, and vehicle platforms, which equipment and network tasks does the skill level 1 paragraph group together?
Installing, deploying, maintaining, troubleshooting, and assisting the GPU with POR and COTS communications equipment, including mission command systems, communications and electronics, COMSEC devices, telephone wire, LANs, and routers; performing field-level unit maintenance and preparing maintenance and supply requests; disseminating and enforcing signal policies; installing, operating, and maintaining retransmission (RETRANS) operations and performing PMCS on assigned vehicles and generators; and providing access to network capabilities and performing net-control-station and network-management operations for tactical radio networks and automated LANs.
DA Pam 611-21, MOS 25U, paragraph a(1) (October 2026 chapter 10C copy) (MOSC 25U1O). Ties SL1 equipment and network tasks together for review; the existing three-places, IOM, maintenance-level, and PMCS cards remain. The pamphlet prints “IOMs RETRANS operations”; this card uses installs, operates, and maintains retransmission operations, matching the existing IOM card.
25U (review): How do 25U duties change from skill level 1 to skill level 3?
Skill level 2 still does the SL1 work and adds supervising and training, supervising field-level maintenance and RETRANS and PMCS, and recognizing electronic countermeasures (ECM) and implementing electronic counter-countermeasures (ECCM). Skill level 3 adds planning the same support and integrating signal systems and networks with adjacent units.
DA Pam 611-21, MOS 25U, paragraphs a(2)–(3) (October 2026 chapter 10C copy) (MOSC 25U2O and 25U3O). Complements the existing “ECM and ECCM first appear at skill level 2” card by showing the SL3 planning and adjacent-unit integration tasks.

25U School graduation standards

Source: 369th Signal Battalion, Delta Company page, cybercoe.army.mil (15th Signal Brigade / 369 SB / 369 D Co), Internet Archive snapshot 16 Jul 2026 (saved as sources/web/369th_d_co_25u_20260716.txt). Public information only. Verify current editions. Complements mos-25u-signal-support.txt and later 25U files and does not repeat the Fort Gordon AIT-location card. The unit page still titles the MOS “Signal Support Systems Specialist”; DA Pam 611-21 ch. 10C (October 2026 copy) uses “Signal Operations Support Specialist.”

25U: How long is 25U AIT on the 369th Signal Battalion Delta Company calendar?
18 weeks, day shift, at Delta Company, 369th Signal Battalion, Fort Gordon, GA. That length comes from the unit page captured 16 July 2026; verify the current length with the school. The same page still titles the MOS “Signal Support Systems Specialist,” while DA Pam 611-21 10C uses “Signal Operations Support Specialist.”
369th Signal Battalion, Delta Company page, Internet Archive snapshot 16 Jul 2026: “25U / Signal Support Systems Specialist / 18 Weeks / Day Shift”; contact block lists Building 29714, Barnes Avenue, Fort Gordon, Ga.
25U: When does the 369th D Co calendar schedule the Phase V and Phase V+ exams?
Phase V Exam in week 2 and Phase V+ Exam in week 9, with room inspections. The July 2026 page also lists “ACFT” events those weeks; the Army Fitness Test has since replaced the ACFT (Army Directive 2026-13). The page does not publish exam passing scores, and none are given here.
369th Signal Battalion, Delta Company page, Internet Archive snapshot 16 Jul 2026, WK 2: “ACFT #1, Room Inspection, Phase V Exam, MRT”; WK 9: “ACFT #2, Room Inspection, Phase V+ Exam, MRT.” Army Directive 2026-13 replaced the ACFT with the Army Fitness Test. Fitness scores are not carded.
25U: What culminating events does the 369th D Co 25U calendar list at the end of the course?
Week 17 is the FTX, induction ceremony, and out-processing. Week 18 is out-processing, graduation, and PCS.
369th Signal Battalion, Delta Company page, Internet Archive snapshot 16 Jul 2026, WK 17: “FTX, Induction Ceremony, Out-processing”; WK 18: “Out-processing, Graduation, PCS.”
25U: What certification-related event does the 369th D Co calendar list in week 14?
Security+ (SEC+) voucher preparation. The page does not say that passing Security+ is required to graduate.
369th Signal Battalion, Delta Company page, Internet Archive snapshot 16 Jul 2026, WK 14: “SEC+ Voucher Preparation, MRT.”

25U – Signal Operations Support Specialist

Source: DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-25U); DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-25Z); DA Pam 611-21 ch. 10 MOS/skill-level classification listing (chapter-10-base); ATP 6-02.53 (31 Jul 2025); ATP 6-02.75 (18 May 2020); ATP 6-02.70 (16 Sep 2025); FM 6-02 (13 Sep 2019); Army Communicator, Oct 2021 ("CMF 25 MOS Convergence"); Army Communicator, Spring 2024; HQDA GO 2025-15 (11 Jun 2025). Verify current editions.

25U: What is the primary role of the 25U?
Status: current MOS (DA Pam 611-21 ch. 10C). To install, operate, maintain and troubleshoot Army radio systems (vehicular and dismounted) and provide signal support for units: network management for IP-based radio networks, LANs and routers, field expedient antennas, COMSEC devices, and retransmission (RETRANS) operations.
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-25U) para a. The earlier "often the only signal Soldier in a company or battalion S6" wording is not in the source and was removed
25U: What MOS was merged into 25U in 2021?
25C (Radio Operator-Maintainer) merged with 25U to form the revised 25U, Signal Operations Support Specialist, effective 1 Oct 2021 (Phase 1 of Signal Enlisted MOS Convergence).
Army Communicator, Oct 2021 ("CMF 25 MOS Convergence"); Army Communicator, Spring 2024
25U: Where is 25U AIT?
Fort Gordon, GA. The 25U course is conducted under the U.S. Army Signal School. Check the current course length on goarmy.com.
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-25U) para b(7); HQDA GO 2025-15 (11 Jun 2025) para 1 (Fort Eisenhower redesignated Fort Gordon)
25U: What equipment does a 25U commonly work with?
Tactical radios (e.g., AN/PRC-117G, AN/PRC-148/152/158/163 series, SINCGARS-family vehicular radios), COMSEC fill devices, antennas, mission command systems, and basic networking equipment.
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-25U) para a(1) (MCS, C&E, COMSEC devices, telephone wire, LANs and routers); ATP 6-02.53 (31 Jul 2025) paras 1-43 (SINCGARS), 2-35 and D-15 (AN/PRC-117F/G, -148, -152, -158, -162, -163)
25U: What is COMSEC?
Communications security – measures to protect communications, including cryptographic keys, devices, and procedures.
ATP 6-02.75 (18 May 2020) para 1-3 (quoting JP 6-0)
25U: What is a fill device used for?
Loading cryptographic keys and data (such as frequency hopping data) into radios (e.g., the Simple Key Loader, SKL, or newer Next Generation Load Device).
ATP 6-02.75 (18 May 2020) paras 2-6 and 3-12 to 3-14 (keys loaded into fill devices; Simple Key Loader). The Next Generation Load Device is not named in the pubs checked
25U: What doctrine covers tactical radio techniques?
ATP 6-02.53, Techniques for Tactical Radios and Retransmission (31 Jul 2025 edition).
ATP 6-02.53 (31 Jul 2025) title page (supersedes the 13 Feb 2020 edition; active on APD)
25U: What is SINCGARS?
Single Channel Ground and Airborne Radio System – a VHF-FM combat net radio family that supports frequency hopping.
ATP 6-02.53 (31 Jul 2025) para 1-43 (SINCGARS is the predominant means of operating command networks), paras 2-32 and I-76 (single-channel and frequency hopping modes), para 2-35 (FM signal retransmission with SINCGARS) and app. I, para I-44 (SINCGARS and VHF line of sight)
25U: What is the PACE plan?
Primary, Alternate, Contingency, Emergency – a prioritized communications plan ensuring redundancy.
ATP 6-02.53 (31 Jul 2025) para 1-45 and table 3-1
25U: What is a SOI?
Signal Operating Instructions – contain call signs, frequencies, challenge/passwords, and other communications data. It is a controlled item.
ATP 6-02.70 (16 Sep 2025) paras C-22 to C-24 (call signs, frequencies, running passwords, sign/countersign; classified at the level of its contents); ATP 6-02.53 (31 Jul 2025) para 3-52
25U: What are the three basic radio modes for SINCGARS-type radios?
Single channel (plain), frequency hopping, and (with COMSEC) cipher text/secure modes.
ATP 6-02.53 (31 Jul 2025) paras I-75 and I-76 (single-channel and frequency hopping modes; ciphertext operation with COMSEC equipment), para 2-32. Front-panel mode settings are in the radio TMs, which were not checked
25U: What are common factors that degrade radio range?
Terrain, vegetation, buildings, weather, antenna height/type, power output, and interference.
ATP 6-02.53 (31 Jul 2025) paras 2-22, E-2 and E-18 (terrain, heavy vegetation, mountains and dry desert soil reduce range), para G-16 (urban line of sight), paras H-87 and G-11 (antenna height)
25U: How can you improve line-of-sight radio range?
Raise or relocate the antenna, use a higher-gain antenna, use a retransmission site, or reposition to higher ground.
ATP 6-02.53 (31 Jul 2025) para H-64 (change antenna height, move the antenna), para G-45 (antenna positioning), para A-33 (retransmission site increases effective range)
25U: What is a retransmission (retrans) site?
A radio station that receives and rebroadcasts signals to extend the range of a net.
ATP 6-02.53 (31 Jul 2025) paras 2-31 to 2-35; DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-25U) para a
25U: What are electromagnetic signature concerns for radio operators?
Emissions can be detected and located by the enemy; minimize transmission time and power, use directional antennas, and practice emission control (EMCON).
ATP 6-02.53 (31 Jul 2025) paras 3-32 and 3-51 (EMCON planning; minimize the unit’s electromagnetic signature) and table A-5 (emission control conditions)
25U: What is a net control station (NCS)?
The station responsible for establishing and controlling a radio net, enforcing discipline, and authenticating stations.
ATP 6-02.53 (31 Jul 2025) para 2-33 (NCS controls traffic and enforces circuit discipline) and para E-4; authentication procedures are in the SOI (ATP 6-02.53 (31 Jul 2025) para 3-52)
25U: What safety concerns apply when erecting antennas?
Avoid overhead power lines, follow mast guying procedures, ground equipment, and keep clear of RF hazard zones during transmission.
ATP 6-02.53 (31 Jul 2025) DANGER note after para H-129 (overhead power lines); TC 6-02.6 (22 Nov 2017) para 1-2 (grounding); DA Pam 40-506 (15 Jul 2009) para 5-28 (RF radiation hazards). ATP 6-02.53 para H-161 covers antenna-guy repair and stabilization, but mast guying steps for erection are in the antenna TMs, which were not checked
25U: What is a 25U's role in the S6 section?
Plan and manage unit communications, maintain radios and COMSEC accountability, support CP setup, and train unit operators.
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-25U) paras a(3) and a(4) (plans and supervises unit signal systems, COMSEC devices, maintenance and supply requests; develops battalion and company signal training; integrates signal systems with adjacent units)
25U: What is the skill progression for 25U?
SL1 (E3-E4) installs and maintains unit communications equipment, LANs, routers and COMSEC devices and runs RETRANS and NCS operations; SL2 (E5) supervises and trains, and recognizes ECM and applies ECCM; SL3 (E6) plans and supervises and integrates signal systems with adjacent units; SL4 (E7) also plans signal logistics, develops battalion and company signal training and advises commanders; at MSG (E8), 25U converts to 25Z.
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-25U) paras a(1)-(4); DA Pam 611-21 ch. 10 MOS/skill-level classification listing (chapter-10-base) (25U1 E3-E4, 25U2 E5, 25U3 E6, 25U4 E7; 25U5 converts to 25Z, 01 Oct 2025); DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-25Z). 10C does not name specific duty positions such as team leader or brigade signal NCO
25U: What is TAK/ATAK in a tactical context?
Team Awareness Kit (Android Team Awareness Kit) – situational awareness software used on end-user devices for position sharing and mapping. Configuration varies by unit.
Unofficial – common unit practice/SOP; not found in official doctrine