Soldier Study Guide · MOS study guides

68P Radiology Specialist study guide

127 flashcards in 9 modules. Search and study in the interactive app.

Study MOS 68P (Radiology Specialist) with plain-language flashcards for your Army job, board prep, and related tasks. Check current Army publications for the latest updates.

Looking for a different job? Browse all Army MOS flashcards.

Study modules

68P – Part 3: Qualifications, Radiographic Positioning & Technique (IR Size, SID, Tube Angles), Shielding, CT Contrast Safety, Imaging Plates/PACS, Protective Device QC, Radiation Safety Program

Source: DA Pam 611-21 (Nov 2025 Smartbook, ch. 10C 10-68P); STP 8-68P15-SM-TG (Apr 2026, public release)

68P part 3: What physical profile and ASVAB score does 68P require?
Profile 222221 and a minimum of 101 in aptitude area ST (effective 9 Oct 2023), with finger dexterity in both hands.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para b(2), b(4) and b(5)(a))
68P part 3: What math prerequisite does 68P have?
One year of high school algebra or one semester of college algebra with a "C" or 74%+. Transcripts are required.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para b(6))
68P part 3: What pregnancy requirement applies to 68P initial award?
Females must not be pregnant.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para b(7))
68P part 3: What qualifies a civilian radiographer under ACASP for 68P?
A JRCERT-accredited radiography program (or equivalent) plus ARRT certification or an unrestricted state license. A limited state license or permit doesn't qualify.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para b(10)(a))
68P part 3: Who supervises an ACASP 68P's proficiency training?
A radiologist (AOC 61Q or 61R) or an NCO qualified in 68P, at initial duty assignment.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para b(10)(b))
68P part 3: Which physical traits does 10C list as needed for radiology specialists?
Good eye-hand coordination, manual dexterity, no aversion to blood, and the ability to stand for long periods.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para a)
68P part 3: What standard source-to-image distance do most STP x-ray tasks use?
40 inches, with the tube perpendicular to the image receptor unless an angle is specified.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0113, 081-68P-0120 and 081-68P-0122
68P part 3: When does the STP call for a 72-inch SID?
For the lateral sternum view (to reduce magnification), and for the lateral view in the spine task.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0125 and 081-68P-0130
68P part 3: Why must mAs and kVp be set properly?
To minimize patient radiation dose while enhancing image quality.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0113, step 4 note
68P part 3: How is a body part measured before setting technique?
Through the entry-exit site of the central ray.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0113, step 4
68P part 3: What must each long-bone view include?
The joint nearest the injury site.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0122
68P part 3: What IR size is used for femur and tibia-fibula views?
14x17-inch. For taller patients, the tib-fib IR can be placed diagonally.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0122 and 081-68P-0120
68P part 3: What IR sizes are used for knee and patella views?
10x12-inch for each knee view, and 8x10-inch for patella views.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0121
68P part 3: What tube angle is used for the lateral knee?
5–7 degrees cephalic, with the knee flexed 20–30 degrees.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0121
68P part 3: When may the acutely flexed tangential patella view be attempted?
Only after other projections have ruled out a patella fracture.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0121
68P part 3: Where does the lead apron go for patella and ankle x-rays?
Across the entire pelvic area.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0121 and 081-68P-0117
68P part 3: Where is the central ray for the AP shoulder?
Perpendicular, 1 inch inferior to the coracoid process, with the coronal plane rotated 10–15 degrees toward the affected side.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0113
68P part 3: What IR is used for AC joint views, and how are they taken?
A crosswise 14x17-inch IR (or two 8x10s side by side for broad patients), AP only: first without weights, then with the patient holding at least 5 lb in each hand.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0113
68P part 3: What tube angle is used for the AP clavicle axial view?
15 to 30 degrees cephalad.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0113
68P part 3: What does the lateral scapula view best show?
A fracture of the body of the scapula.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0113
68P part 3: How are the legs positioned for an AP pelvis?
Extended and rotated medially 15–20 degrees, so the femoral heads and necks are parallel to the IR.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0124
68P part 3: How far is each thigh abducted for a frog-leg view?
About 40 degrees from vertical.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0124
68P part 3: What does an upright AP abdomen show?
Air-fluid levels under the diaphragm, if present.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0129
68P part 3: Where does the lead apron go for chest views?
Around the patient's waist. All clothing from the waist up is removed and a gown worn.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0125
68P part 3: What IR sizes are used for chest/ribs and sternum?
14x17-inch for chest and ribs, and 10x12-inch for sternum.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0125
68P part 3: What is the critical caution before cervical spine x-rays on trauma patients?
Don't remove the cervical collar, as it may cause further spinal injury.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0130
68P part 3: What tube angles does the STP give for the AP sacrum and AP coccyx?
15 degrees cephalic for the sacrum, and 10 degrees caudad for the coccyx.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0130
68P part 3: What collimation is used for the open-mouth C-spine view?
6x6 inches. The patient opens the mouth as wide as possible, moving only the lower jaw.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0130
68P part 3: Which items must be removed before a spine x-ray?
Foreign objects, clothing over the area, items around the neck, and removable dental work.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0130
68P part 3: What tube angles are used for PA and AP Caldwell views?
15 degrees caudad for the PA Caldwell, and 30 degrees caudad for the AP Caldwell.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0135
68P part 3: What collimation is used for sinus and TMJ x-rays?
6x6 inches for paranasal sinuses, and 4x4 inches for the TMJ.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0135
68P part 3: Why is a patient seated for several minutes before sinus views?
To let free fluids and air settle.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0135
68P part 3: What tube angle is used for the AP foot?
10 degrees cephalic.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0117
68P part 3: How is the central ray angled for the axial calcaneus view?
40 degrees toward the heel.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0117
68P part 3: How is a finger x-ray IR divided?
An 8x10-inch IR is divided in thirds crosswise for finger and thumb views, and collimated to four sides of the finger.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0108
68P part 3: Where is the central ray for a scaphoid view?
Toward the scaphoid, 3/4 inch medial and 3/4 inch distal to the lateral styloid, with the hand in ulnar flexion.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0108
68P part 3: What instruction is given just before exposure?
"DO NOT MOVE," and hold the breath, to prevent motion.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0120 and 081-68P-0122
68P part 3: What is done to images after exposure?
Rotate, flip, collimate and label appropriately.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0113 and 081-68P-0174
68P part 3: What should a pregnant patient do before an x-ray?
Consult the referring physician about the risks of radiation exposure.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0120 and 081-68P-0122
68P part 3: How long should a CR reader self-test take?
Under 5 minutes from power-on. Otherwise notify qualified repair personnel.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0174
68P part 3: After imaging-plate processing, how is a study sent and located in PACS?
Send the study from the modality to PACS, log into PACS and RIS, and search by patient ID or medical record number, name, or accession number.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0174 (PACS steps)
68P part 3: What must be checked if a patient had a contrast study in the last 72 hours?
Labs. Notify the radiologist or provider before giving contrast if labs exceed acceptable limits.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-1001 and 081-68P-1002
68P part 3: What eGFR does the STP list as acceptable renal function for IV contrast?
Greater than 30 mL/min/1.73 m², along with creatinine and BUN levels.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-1001
68P part 3: What must the patient be told before contrast?
About potential adverse reactions to contrast media.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-1001 and 081-68P-1002
68P part 3: What's done if IV infiltration is seen during a CT angiography injection?
Stop the injection immediately and start an IV at a different site.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-1007
68P part 3: What is a region of interest (ROI) used for in CT angiography?
A graphic overlay on the vessel that sets the contrast threshold, so the scanner can auto-start.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-1007
68P part 3: How often are lead aprons, gloves and thyroid collars QC-tested?
When new, and with annual spot checks, recorded on the annual QC checklist.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0165
68P part 3: How are protective devices scanned for defects?
With an image-intensified fluoroscopy unit, under the medical physicist, RPO or NCOIC.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0165, step 4
68P part 3: What warning must every x-ray control panel display?
A readable warning that the unit may be dangerous to patient and operator unless safe exposure factors and instructions are followed.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-0165, step 2 note
68P part 3: Which records are reviewed when managing a radiation safety program?
Training, dosimetry, survey, inventory, transportation and incident records, plus radiological operations, using the radiation safety checklist.
STP 8-68P15-SM-TG (Apr 2026), task 081-68P-4001

68P – Part 4: Contrast and IV Steps, Radiation Safety, Trauma Positioning, and Career Board Standards

Source: STP 8-68P15-SM-TG (Soldier's Manual and Trainer's Guide, MOS 68P, 30 Apr 2026); HRC Army NCO Board Guidance, CMF 68 (as of 15 Sep 2025)

68P part 4: Which lab value ranges for BUN and creatinine (mg/dL) does the STP list before giving IV contrast for a CT spine study?
As printed: BUN 8 to 25 mg/dL and creatinine 1.3 to 2 mg/dL (with eGFR above 30 mL/min/1.73 m²); labs, contrast and history go on the chart. The creatinine range looks like a misprint (normal adult creatinine is about 0.5–1.3 mg/dL), so follow the radiologist and local SOP.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-1003, step 3c(2)-(3)
68P part 4: Before administering IV contrast medication for a CT study, what approval and verification steps are required?
Get the radiologist's or attending physician's signature on the chart approving the exam and contrast; verify the patient with at least two identifiers; check the screening form with the patient; and verify the correct contrast, dose, route, and time before giving it per local SOP, then monitor the patient during and after.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-1003, step 3c(4)-(8)
68P part 4: How is the IV started for a CT contrast study, and what do you check before connecting the injector?
Disinfect the site with alcohol, flush with a 5 mL bolus of normal saline, gain vascular access, and check for infiltration of fluid into surrounding tissue before connecting the auto-injector tubing. If infiltration is seen, stop and start the IV at a different site.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-1003, step 4
68P part 4: When setting the CT auto-injector for an IV contrast injection, what is set and checked, and what factors affect the PSI?
Set the flow rate, volume (mL), and PSI per the radiologist's or provider's order; verify the syringe holds at least the volume to be injected; confirm no air remains in the IV tubing; then arm the syringe. PSI is affected by catheter gauge, heplock position and location, procedure type, patient pathology, and age.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-1006, step 3 and caution
68P part 4: What radiation safety caution applies to who may be in the x-ray room during an exposure?
The room must be clear of everyone except the patient. Anyone who must stay in the room must be shielded and protected.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-0113 caution (repeated in the other x-ray tasks)
68P part 4: What radiation exposure caution applies when performing protective device quality control tests?
Ensure thermoluminescent dosimeter (TLD) badges and appropriate shielding are worn.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-0165 caution
68P part 4: What electrical safety checks come first when setting up the deployable medical system portable radiographic unit?
Make sure the power switch is off, connect the AC power cord to a grounded outlet, and check the machine's label for the correct AC input voltage and amperage before selecting kVp and mAs.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-0302, steps 1-3
68P part 4: What risk does the STP warn about for radiographic and CT units under degraded networks or a degraded electromagnetic spectrum?
The units become inoperable. For the portable radiographic unit, refer to the physician for guidance on diverting casualties.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-0302 caution; task 081-68P-1006 special condition
68P part 4: After auditing radiology sections for radiation safety, how is the audit documented and reported?
Prepare a memorandum outlining what was evaluated and the results, including a plan of action to correct any deficiencies, and communicate the results to the NCOIC, OIC, and radiation safety officer.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-4001, steps 5-6
68P part 4: With possible wrist trauma or fracture, when may the ulnar flexion view be attempted?
Only after the routine series is completed to evaluate for possible fractures of the distal forearm or wrist.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-0110 warning
68P part 4: For a trauma patient with a possible humerus fracture, how may the exam be positioned and where is the image receptor placed?
The exam may be done supine or upright depending on the patient's condition, and for children or trauma the IR may be placed on the tabletop instead of in the bucky (14x17-inch IR for both views).
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-0112, steps 5-7
68P part 4: How is the patient positioned for CT of the cervical spine versus the thoracic and lumbar spine?
C-spine: supine, head toward the gantry, arms at the sides, head in the head cradle without the angle cushion. T- and L-spine: supine, head away from the gantry, arms above the head. Transfer to a radiolucent spine board if necessary.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-1003, step 5e
68P part 4: Which civilian credentials earn a 68P a "Most Qualified" (MQ) training rating on the career board guidance?
Two or more of: ARRT Radiography (RT-R), Breast Sonography (BS), or Certified Nuclear Medicine Technologist (CNMT).
HRC Army NCO Board Guidance, CMF 68 (15 Sep 2025), MOS 68P & 68Q training
68P part 4: Which credential earns a 68P a "Highly Qualified" (HQ) training rating on the career board guidance?
One of: the Fluoroscopy exam, Radiography (R), or Cardiac Interventional Radiography (CI).
HRC Army NCO Board Guidance, CMF 68 (15 Sep 2025), MOS 68P & 68Q training
68P part 4: Which career developmental positions earn 68P NCOs a "Most Qualified" rating at SSG, SFC, and MSG?
SSG: Squad/Section Leader or Radiology NCO (selected to serve as Platoon Sergeant). SFC: Senior Radiology NCO, Detachment Sergeant, Platoon Sergeant, or First Sergeant. MSG: First Sergeant. (HQ MSG: Chief Radiology NCO.)
HRC Army NCO Board Guidance, CMF 68 (15 Sep 2025), 68P developmental assignments

68P – Part 5: Examination Terminal Duties, Technique Chart Methods and Radiation Safety, Field X-ray Set Safety, CT Daily QA Safety

Source: STP 8-68P15-SM-TG (30 Apr 2026)

68P part 5: What duties does a 68P perform to start up the imaging equipment examination terminal and send images?
Confirm all PC hardware is connected to the computed radiography workstation and to power; check the CPU power indicator (if it doesn't light, check the connection and notify qualified repair personnel if damage is suspected); power on the monitor and CPU; log in; open the application; manipulate the image as needed; and transmit it for interpretation, per the manufacturer's manual and TB MED 521.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-0325
68P part 5: Before developing a radiographic technique chart, what radiation safety and equipment checks apply?
Wear thermoluminescent dosimeter badges and appropriate shielding (possible radiation exposure). Verify the unit passed scheduled TMDE calibration and routine QC; a newly acquired unit must first have acceptance testing by a medical or health physicist per ACR and AAPM guidelines. If collimation, AEC, or APR override malfunctions, start a work order with medical maintenance and do not use the unit until recalibrated and QC'd by a qualified engineer or health physicist.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-2017, caution, step 1 and notes
68P part 5: Which methods and factors are used to build a technique chart, and how is it approved?
Methods: body habitus (heavyset, normal, slender), variable kVp (mAs constant, kVp varied with thickness), optimum kVp (kVp and SID constant, mAs varied), or AEC/APR. Factors: film holder and screen speeds, grid ratios, tube limits and rectification (three-phase heat units differ from single-phase), patient thickness, and collimation (tighter collimation needs more technique). Record adjustments and reasons, get approval from the QC technologist or chief radiologist, and post the chart by the control panel.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-2017, steps 2-7
68P part 5: When managing x-ray field lightweight materiel sets, what radiation safety rule applies to serviceability checks?
Due to potential radiation exposure, do not activate or test radiological equipment for serviceability. Instead, supervise layout and inventory of all radiology supplies and equipment, request issue or turn-in of missing or excess items, send broken equipment or items due scheduled maintenance to medical maintenance, sign the DA Form 2062 hand receipt and other documentation, and store equipment in the designated location.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-2018
68P part 5: During CT daily quality assurance with a phantom, which steps are safety-restricted, and what is the start-up and shutdown order?
Do not perform tube conditioning, air calibration (up to about 30 minutes), or any scan with personnel in the scanner room. Start-up: wall circuit breaker, UPS, all CPUs, monitors, log-in, then tube conditioning and air calibration; position the phantom with the lasers, tilt the gantry to zero, scan, and send images via RIS/PACS. Shut down in reverse order of power-up.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-1000

68P – Part 6: HQ Developmental Assignments; Field Hospital Radiology and CT Sections

Source: CMF 68 NCO Board Guidance (19 Sep 2025), 68P developmental assignments; ATP 4-02.10 (15 Aug 2025), paras 2-56, 2-57

68P part 6: Which career developmental assignments earn a 68P SSG or SFC a "Highly Qualified" (HQ) rating on the NCO board?
HQ SSG: Radiology Sergeant/NCO, or 12 months of Squad Leader experience at current grade (HQ rating and mid-level enumeration). HQ SFC: Senior Radiology NCO, or 12 months of Platoon Sergeant experience (HQ rating and mid-level enumeration).
CMF 68 NCO Board Guidance (19 Sep 2025), 68P developmental assignments
68P part 6: What is the role of the Role 3 field hospital radiology section where 68Ps work, and on what schedule?
Radiological services to all areas of the hospital, including triage and pre-operative, on a 24-hour basis. It also provides daily radiology logistics requirements and statistical data to the nursing services section.
ATP 4-02.10 (15 Aug 2025), para 2-56
68P part 6: What is the role of the field hospital's computerized tomography (CT) section?
CT and radiological services for all areas of the hospital, operating on a 24-hour basis, and daily CT logistics requirements and statistical data to the nursing services section.
ATP 4-02.10 (15 Aug 2025), para 2-57

68P – Part 7: Qualifying Standards (Radiology Specialist)

Source: DA Pam 611-21 ch. 10C (Oct 2026 copy, eff 202610), para 10-68P b

68P qualifying standards: What physical demands rating does 68P carry?
Moderate (Gold).
DA Pam 611-21 ch. 10C (eff 202610), para 10-68Pb(1)
68P qualifying standards: What security clearance does a 68P need, and when?
An interim eligibility clearance or higher is required for promotion to MSG and SGM, per AR 600-8-19.
DA Pam 611-21 ch. 10C (eff 202610), para 10-68Pb(3)
68P qualifying standards: What are the minimum OPAT scores for 68P?
Standing long jump 120 cm, seated power throw 350 cm, strength deadlift 120 lb, and interval aerobic run 36 shuttles, in the Moderate (Gold) category.
DA Pam 611-21 ch. 10C (eff 202610), para 10-68Pb(5)(b)
68P qualifying standards: What math education does 68P require, and what proof?
One year of high school algebra or one semester of college algebra with a "C" or 74% or higher. A high school or college transcript is required.
DA Pam 611-21 ch. 10C (eff 202610), para 10-68Pb(6)
68P qualifying standards: What pregnancy standard applies to initial award of 68P?
Females must not be pregnant.
DA Pam 611-21 ch. 10C (eff 202610), para 10-68Pb(7)
68P qualifying standards: What is the general criminal-history bar for 68P?
No history of a felony conviction.
DA Pam 611-21 ch. 10C (eff 202610), para 10-68Pb(8)
68P qualifying standards: Convictions for which kinds of crimes disqualify a 68P?
Crimes involving weapons, ammunition, explosives or arson, illegal drug activity, violence against persons, animals or property, and sexual misconduct.
DA Pam 611-21 ch. 10C (eff 202610), para 10-68Pb(9)
68P qualifying standards: What happens when a former 68P serving in another MOS reclassifies back into 68P?
The proponent reviews them to validate their skills during the reclassification process.
DA Pam 611-21 ch. 10C (eff 202610), para 10-68Pb(11)

68P – Part 8: School Graduation Standards (Radiology Specialist)

Source: AR 350-1 (1 June 2025), para 3-13; TRADOC Administrative Publications listing of TR 350-6 (28 Aug 2025), accessed 23 Nov 2026; DA Pam 600-25 CMF 68 (22 Aug 2023); MEDCoE Credentialing Program (MEDCP) page (medcoe.army.mil/medcp), accessed 23 Nov 2026; DA Pam 600-25 CMF 68 (22 Aug 2023), para 15-4a

68P school graduation standards: Who establishes Initial Entry Training (IET) graduation requirements, and which regulations’ standards must AIT or OSUT graduates meet?
TRADOC establishes IET graduation requirements. Graduates of AIT or OSUT will also meet the standards of AR 40-501, AR 600-9, and AR 611-1.
AR 350-1 (1 June 2025), para 3-13c
68P school graduation standards: Under 10 USC 671, when may a Soldier be assigned to active duty on land outside the United States and its territories and possessions?
Not until the Soldier has completed IET within the Army. In a war or national emergency declared by Congress or the President, the required IET period may not be less than 12 weeks, except for Soldiers already credentialed in a medical profession or occupation and serving in a health-care occupational specialty.
AR 350-1 (1 June 2025), para 3-13 (citing 10 USC 671)
68P school graduation standards: What current TRADOC regulation prescribes enlisted IET policies and administration, including graduation policy?
TRADOC Regulation 350-6, Enlisted Initial Entry Training Policies and Administration. The edition listed on the TRADOC Administrative Publications site is dated 28 August 2025. This guide does not quote event-level fitness or written-test passing scores from it because the official current PDF was not independently verified from adminpubs.tradoc.army.mil during this build, and older editions are superseded.
TRADOC Administrative Publications regulations listing (adminpubs.tradoc.army.mil/regulations.html), TR 350-6 dated 28 Aug 2025, accessed 23 Nov 2026 (America/New_York). Event-level graduation scores from older TR 350-6 editions are not used here because they are superseded.
68P school graduation standards: How long is 68P AIT, and how are its two phases set up?
The combined course length is 44 weeks, 2 days. Phase I is 24 weeks, 2 days at METC, JBSA–Fort Sam Houston. Phase II is 22 weeks at a designated military treatment facility.
DA Pam 600-25 CMF 68 (22 Aug 2023), para 15-4a
68P school graduation standards: Is a civilian certification required to graduate 68P AIT?
No. MEDCoE lists 68P among the MOSs for which it funds voluntary Institutionally Delivered Credentials, but it is not mandatory to obtain a credential for any MOS other than 68C or 68W in order to graduate.
U.S. Army Medical Center of Excellence, MEDCOE Credentialing Program (MEDCP) page, https://medcoe.army.mil/medcp/, accessed 23 Nov 2026 (America/New_York)

68P – Part 9: Final Exam Study Guide (Radiology Specialist)

Source: Public official sources as of 23 Nov 2026; STP 8-68P15-SM-TG (30 Apr 2026); DA Pam 611-21 ch. 10C (eff 202610); DA Pam 600-25 CMF 68 (22 Aug 2023)

68P study review: Do public official sources publish the 68P AIT final exam questions or a numeric end-of-course passing score?
No. Public official sources used for this guide do not publish the 68P AIT final-exam item bank or a MOS-specific end-of-course passing score. This guide reviews key tasks and facts from official publications; it is not a set of official exam answers.
Public-source limit as of 23 Nov 2026 (America/New_York): no public official AIT program of instruction or end-of-course test publication for this MOS was available for this build.
68P study review: Which official public Soldier's Manual lists 68P critical tasks, and what is its edition?
STP 8-68P15-SM-TG, Soldier's Manual and Trainer's Guide, MOS 68P Radiology Specialist, Skill Levels 1-5, dated 30 April 2026. It is approved for public release.
STP 8-68P15-SM-TG (30 Apr 2026), title page and distribution restriction statement
68P study review: What skill level 1 subject areas does the 68P MOS training plan use?
Subject Area 4: Diagnostic Imaging, and Subject Area 5: Quality Control.
STP 8-68P15-SM-TG (30 Apr 2026), ch. 2, table 2-4, Skill Level 1, Subject Areas 4 and 5
68P study review: What kinds of diagnostic-imaging critical tasks does the 68P Soldier's Manual list at skill level 1?
They include performing radiographs of the chest, extremities, pelvis, spine, abdomen, shoulder, and head; processing an imaging plate and retrieving images from a digital archive; operating a Deployable Medical System portable radiographic unit, a portable C-arm, and imaging equipment workstations; and performing computed tomography of the chest, head, neck, spine, abdomen, pelvis, and extremities, plus CT angiography and operation of a CT auto-injector.
STP 8-68P15-SM-TG (30 Apr 2026), ch. 2, table 2-4, Skill Level 1, Subject Area 4
68P study review: What quality-control critical tasks does the 68P Soldier's Manual list at skill level 1?
Perform protective device quality control tests, and perform quality assurance and quality control on the computed tomography scanner.
STP 8-68P15-SM-TG (30 Apr 2026), ch. 2, table 2-4, Skill Level 1, Subject Area 5 (tasks 081-68P-0165 and 081-68P-1000)
68P study review: What radiographic principles and foundational topics does Phase I of 68P AIT cover?
Radiographic procedures, radiation protection, imaging equipment and techniques, and quality assurance, plus radiation biology, radiation physics, medical terminology, concepts of patient care, radiographic pathology, and medical ethics and law. Phase I also includes laboratory exercises to test theories and concepts, with a focus on developing manual skills before clinical application.
DA Pam 600-25 CMF 68 (22 Aug 2023), para 15-4a
68P study review: What is the emphasis of Phase II of 68P AIT?
On-the-job training in the clinical environment, performing procedures and exams on actual ill or injured patients under the guidance of qualified radiographers and radiologists, with emphasis on acquiring competency in those procedures and exams.
DA Pam 600-25 CMF 68 (22 Aug 2023), para 15-4a
68P study review: Besides operating equipment, what patient-care and administrative actions does DA Pam 611-21 list for a skill level 1 radiology specialist?
Read and interpret radiographic requests and physician's orders; provide patient care in the radiology area; apply radiation, electrical, and mechanical protective measures; use hospital information systems and perform routine patient administration; and maintain patient locator, radiographic, and report files. The specialist also inspects and performs operator maintenance and packs, unpacks, loads, unloads, assembles, and disassembles radiology equipment and shelters.
DA Pam 611-21 ch. 10C (eff 202610), para 10-68Pa(1)

68P – Radiology Specialist

Source: DA Pam 611-21 (Smartbook, Nov 2025: ch. 10C 10-68P, Fig 10-1); STP 8-68P15-SM-TG, Radiology Specialist SL 1-5 (30 Apr 2026); DA Pam 385-10 (24 Jul 2023) ch. 10; AR 385-10 (24 Jul 2023) ch. 16; DA Pam 40-506 (15 Jul 2009); ATP 4-02.10 (Aug 2025); TB MED 298 (9 May 2019).

68P: What is the primary role of the Radiology Specialist?
Status: current MOS (DA Pam 611-21 ch. 10C). To operate imaging equipment (x-ray, CT, and other modalities) to produce diagnostic images.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para a); STP 8-68P15-SM-TG (30 Apr 2026), ch. 3 (x-ray and computed tomography tasks)
68P: What does ALARA stand for?
As Low As Reasonably Achievable – minimizing radiation exposure.
DA Pam 385-10 (24 Jul 2023), para 10-1; AR 385-10 (24 Jul 2023), paras 16-20 to 16-22 (ALARA investigational levels)
68P: What are the three principles of radiation protection?
Time, distance, and shielding.
DA Pam 40-506 (15 Jul 2009), para 5-23a; TB MED 298 (9 May 2019), para 6-1 (Radiation Safety: time, distance, and shielding)
68P: What civilian registry aligns with 68P?
The American Registry of Radiologic Technologists (ARRT). DA Pam 611-21 accepts ACASP entry for graduates of a JRCERT-accredited radiography program who hold ARRT certification or an unrestricted state license.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para b(10)(a))
68P: Where do 68Ps work?
Hospital radiology departments, clinics, and field hospitals.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para a(3)-(5): radiology activities up to MEDCEN, MEDDAC, or CSH); ATP 4-02.6 (Nov 2022, incl C1), para 1-56 (Role 2 area support squad radiology); ATP 4-02.10 (Aug 2025), para 1-21 (Role 3 radiology and CT)
68P: What is a dosimeter?
A badge worn to monitor a worker's cumulative radiation exposure.
AR 385-10 (24 Jul 2023), paras 16-10 and 16-19 (external dosimetry and dosimetry reporting); STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-0165 (TLD badges)
68P: Why must pregnancy status be checked before imaging?
To avoid unnecessary radiation exposure to a fetus; follow facility screening procedures.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-0113, step 3 note (pregnant patient consults the referring physician on radiation risks)
68P: What is a CT scan?
Computed tomography – x-ray imaging that creates cross-sectional images of the body.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-1002, Perform Computed Tomography of the Chest; ATP 4-02.10 (Aug 2025), para 1-21
68P: What is a FAST exam?
Focused Assessment with Sonography for Trauma – ultrasound to detect internal bleeding (performed by trained providers).
Unofficial – common unit practice/SOP; not found in official doctrine
68P: What is patient positioning's importance in radiography?
Correct positioning produces diagnostic images and avoids repeat exposures.
STP 8-68P15-SM-TG (30 Apr 2026), ch. 3 x-ray tasks (e.g., 081-68P-0113: positioning aids and steps); repeat-exposure rationale – verify locally
68P: What is the inverse square law?
Radiation intensity decreases with the square of the distance from the source – doubling distance cuts exposure to one quarter.
DA Pam 40-506 (15 Jul 2009), para 5-24b(4) (field strength decreases with the inverse square of distance)
68P: What is a contrast agent?
A substance that improves visibility of structures in imaging; patients are screened for allergies and kidney issues.
STP 8-68P15-SM-TG (30 Apr 2026), task 081-68P-1002 (iodinated contrast; inform patient of possible adverse reactions); allergy/renal screening per local SOP
68P: What is the skill progression for 68P?
SL1 (E-3/E-4) performs radiographic examinations and operator maintenance; SL2 (SGT) adds technical guidance, specialized procedures, and supply; SL3 (SSG) complex procedures, radiation-safety inspections, training (medium radiology activity); SL4 (SFC) supervises a large radiology activity; SL5 (MSG) supervises radiology in a MEDCEN, large MEDDAC, or CSH. Fig 10-1 lists 68P at E-3 to E-8; 68Z at SGM.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para a(1)-(5)); Fig 10-1
68P: Where is 68P AIT?
The 68P course is conducted under the auspices of the AMEDD Center and School (MEDCoE) at JBSA–Fort Sam Houston, TX, or Soldiers qualify through ACASP (JRCERT program + ARRT) – verify current length and phases.
DA Pam 611-21 (Nov 2025), ch. 10C (10-68P, para b(10)); MEDCoE Students page (medcoe.army.mil/students)
68P: What is MRI safety's main concern?
The strong magnetic field can turn ferromagnetic objects into projectiles and affect implants; screen everyone entering.
TB MED 298 (9 May 2019), para 6-13 (MRI: metal objects become dangerous projectiles; written for MWD imaging)

CMF 68 – Army Medicine Common Knowledge

Source: DA Pam 611-21 (Smartbook, Nov 2025: ch. 10C, Fig 10-1, Table 10-1); FM 4-02, Army Health System (Nov 2020, C2 Aug 2025); ATP 4-02.1, Army Medical Logistics (Oct 2015); AR 40-66 (Jun 2008, RAR Jan 2010); AR 40-502 (Jun 2019); DA Pam 40-11 (May 2020); MEDCoE students page; AMEDD Center of History & Heritage (regimental insignia). Applies across 68-series MOSs.

CMF 68: Where do most 68-series Soldiers attend AIT?
The Medical Center of Excellence (MEDCoE), Joint Base San Antonio–Fort Sam Houston, TX; some phase II training occurs at Army medical centers – verify per MOS.
DA Pam 611-21 (Nov 2025), ch. 10C (formal-training qualification in each 10-68_ spec: course under MEDCoE/METC auspices); MEDCoE Students page (medcoe.army.mil/students: MEDCoE and METC at JBSA–Fort Sam Houston)
CMF 68: What doctrine describes the Army Health System?
FM 4-02, Army Health System.
FM 4-02 (Nov 2020, C2 Aug 2025)
CMF 68: What are the roles of medical care?
Role 1 (unit-level care: combat medics and the battalion aid station), Role 2 (medical company: greater resuscitative capability, limited x-ray/lab, dental, COSC, and holding up to 72 hours; the Army provides no surgery at Role 2 unless an FST/FRSD is collocated, although NATO Role 2 Basic/Enhanced and joint Role 2 Enhanced include surgery), Role 3 (hospital: resuscitation, initial wound surgery, damage control surgery, postoperative care), Role 4 (CONUS-based hospitals and other safe havens – the most definitive care).
FM 4-02 (Nov 2020, C2 Aug 2025), paras 1-39 to 1-47
CMF 68: What is the Army Medical Department (AMEDD) motto?
The AMEDD Regiment's current motto, on the regimental insignia adopted in 2014, is "Experientia et Progressus" (Experience and Progress). "To Conserve Fighting Strength" – the Medical Field Service School motto and the regimental motto from 1986 to 2014 – still sums up the Army Medicine mission to conserve the fighting strength.
AMEDD Center of History & Heritage, Regimental Heraldic Items (achh.army.mil/regiment/heraldic-distinct); army.mil, "The New AMEDD Regimental Distinctive Insignia" (24 Nov 2014); FM 4-02 (Nov 2020, C2 Aug 2025), para 4-18
CMF 68: What is HIPAA?
The Health Insurance Portability and Accountability Act – protects patient health information; medical personnel must safeguard PHI.
AR 40-66 (Jun 2008, RAR Jan 2010), para 1-4 (HIPAA Privacy Rule compliance; HIPAA privacy officer)
CMF 68: What is the senior enlisted capper for CMF 68?
68Z, Chief Medical NCO (sergeant major).
DA Pam 611-21 (Nov 2025), Fig 10-1 (68Z Chief Medical NCO, grade 9); ch. 10C (10-68Z)
CMF 68: Which 68-series MOSs no longer appear in the Nov 2025 chart?
68N (Cardiovascular Specialist) and 68U (Ear, Nose, and Throat Specialist). Neither is in the Fig 10-1 chart, and Table 10-1 lists both as deleted effective Oct 2021 (202110).
DA Pam 611-21 (Nov 2025), Fig 10-1; Table 10-1 (68N, 68U status D, 202110)
CMF 68: What is universal/standard precautions?
Treating all blood and body fluids as potentially infectious – use gloves, eye protection, and hand hygiene.
DA Pam 40-11 (May 2020), para 7-19 (universal or standard precautions as safe work practices); ATP 4-02.4 (May 2021), para 5-231
CMF 68: What is Class VIII?
Medical materiel – medical supplies and equipment (Class VIIIA) – and blood (Class VIIIB). Army medical logistics also covers medical equipment maintenance, optical fabrication, and medical gases. Medical logisticians and clinical staff both depend on it.
ATP 4-02.1 (Oct 2015), ch. 1 (paras 1-7 to 1-11, Class VIII as a separate class of supply) and Introduction (MEDLOG functions: Class VIIIA, Class VIIIB, maintenance, optical fabrication, medical gases)
CMF 68: What is a battalion aid station (BAS) in terms of role of care?
A Role 1 medical treatment facility that provides first responder and battalion-level treatment and evacuation coordination, usually close to the supported unit. Exact organization varies by unit type.
FM 4-02 (Nov 2020, C2 Aug 2025), paras 1-39 and 1-40
CMF 68: What is the difference between a clinical 68-series MOS and a support 68-series MOS, in general terms?
Clinical MOSs (for example 68W, 68C, 68K, 68P) treat patients or process clinical specimens and images. Support MOSs (for example 68G, 68J, 68A) administer records, medical logistics, or medical equipment so that care can continue. All fall under Army Medicine.
DA Pam 611-21 (Nov 2025), ch. 10C (major duties, 10-68A through 10-68Y)
CMF 68: Why must 68-series Soldiers protect patient information even in a field aid station?
HIPAA and Army privacy rules still apply to protected health information. Share only what is needed for treatment, payment, or official operations, and follow the unit and MTF SOP for field records.
AR 40-66 (Jun 2008, RAR Jan 2010), para 1-4 (HIPAA Privacy Rule compliance)
CMF 68: What is a Medical Equipment Set (MES)?
A standardized assemblage of medical equipment and supplies built for a mission (for example, an aid-station or sick-call set). Contents are authorized by medical logistics documents and can change; use the current set list, not an old memory.
ATP 4-02.1 (Oct 2015), paras 3-10 and 3-50 (MES fielding and management)
CMF 68: What is the usual relationship between a 68W in a line unit and the battalion PA or medical officer?
The medic provides Role 1 care and evacuation under the medical officer's or PA's clinical supervision and the commander's health-service support plan. Scope of practice is set by training, credentialing or certification, and SOP — not by personal preference.
FM 4-02 (Nov 2020, C2 Aug 2025), para 1-40 (Role 1 care by the combat medic, physician, and PA at the BAS); DA Pam 611-21 (Nov 2025), ch. 10C (10-68W)
CMF 68: What is medical readiness, in one sentence?
The status of a Soldier's deployable health, tracked so the commander knows who is available to fight. The Army tracks eight individual medical readiness (IMR) elements: periodic health assessment, deployment-limiting conditions, dental readiness, immunizations, medical readiness lab tests, individual medical equipment, hearing, and vision.
AR 40-502 (Jun 2019), para 2-3 (IMR key elements)
CMF 68: Where should a 68-series Soldier look for official duty and qualification standards for a specific MOS?
DA Pam 611-21, chapter 10C (the current enlisted MOS specification), plus the MOS course map and any MEDCoE guidance. Recruiting websites are useful but not always complete.
DA Pam 611-21 (Nov 2025), ch. 10C
CMF 68: What is a common safety expectation in any 68-series workplace?
Standard precautions, correct sharps disposal, safe lifting of patients and boxes, and equipment-specific rules (radiation, anesthetic gases, laboratory chemicals, or oxygen, as applicable to the MOS). Follow the clinic or laboratory SOP and SDS.
DA Pam 40-11 (May 2020), para 7-19 (standard precautions, safe work practices); MOS-specific detail per clinic/lab SOP and SDS
CMF 68: What enlisted capper already appears for CMF 68, and what should you not assume about "68Z duties"?
68Z is the Chief Medical NCO (sergeant major) capper. Specific 68Z duty descriptions belong in DA Pam 611-21 and the assignment instructions — do not invent a universal 68Z job list.
DA Pam 611-21 (Nov 2025), Fig 10-1; ch. 10C (10-68Z)